SELF-DIAGNOSTIC ALARM CODES
Alarm Display
Problem
Cause
Correc ve Ac on
Frost preven on
sensor and
Abnormal
temperature
sensor value
• Indoor heat exchanger
temperature too low
• TH3 temperature
sensor has a loose or
broken connec on
• Do not use the air
condi oner if ambient
temperature is lower
than 18°C (64°F)
• Contact a quali
fi
ed
service agent
Refrigerant high
pressure switch
• Blocked air
fi
lter
• Blocked / kinked ex-
haust duct
• Ambient temperature
is too high
• Clean air
fi
lter
• Ensure exhaust duct is
not blocked / kinked
• Do not use the air
condi oner if ambient
temperature is higher
than 45°C (113°F)
Abnormal
temperature
sensor value
TH1(Outlet) temperature
sensor has a loose or
broken connec on
Contact a quali
fi
ed service
agent
Abnormal tem-
perature sensor
value
TH2(Inlet) temperature
sensor has a loose or
broken connec on
Contact a quali
fi
ed service
agent
Compressor over-
loaded
• Ambient temperature
is too high
• Unstable voltage
supply
• Defec ve compressor
• Over current relay
defect or broken
connec on
• Do not use the air
condi oner if ambient
temperature is higher
than 45°C (113°F)
• Contact a quali
fi
ed
service agent
• Replace compressor
Drain pump alarm
Drain pump defec ve
or improper hose
connec on (including
kink or blockage)
• Contact a quali
fi
ed
service agent
• Check the hose connec-
on and hose
• Replace drain pump
Abnormal
dehumidi
fi
ca on
sensor value
TH4(Dehumidi
fi
ca on)
sensor has a loose or
broken connec on
Contact a quali
fi
ed service
agent
Table 1- Alarm Codes