Timer Values
•
Applicantion
•
Attribute Type
•
MRP Applicant
•
Periodic Tx
•
Timer Values :
To set the MRP join timer, leave timer and .leave all timers, units is Micro-second.
Three different timers can be configured on this page:
Join Timer :
The default value for Join timer is 200ms.
Leave Timer :
The range of values for Leave Time is 600-1000ms. The default value
for Leave Timer is 600ms.
Leave All Timer :
The default value for Leave All Timer is 10000ms
Application :
Current only supported application is MVRP.
Attribute Type :
Currently only supported Attribute Type is VLAN.
MRP Applicant :
This configuration is used to configure the Applicant state machine behaviour for MRP on a
perticular port locally.
•
normal-participant: In this mode the Applicant state machine will operate normally in
MRP protocol exchanges.
•
non-participant: In this mode the Applicant state machine will not participate in the
protocol operation.
The default configuration is normal participant.
Periodic Tx :
This configuration is used to configure transmission mode and this can be congured either
as enabled or disable. The default value of Periodic Tx is disable.
Auto-refresh :
To evoke the auto-refresh icon then the device will refresh the information automatically.
Upper right icon (Refresh):
You can click them for refresh the MRP Port configuration information by manual.
Buttons:
Save
– Click to save changes.
Reset-
Click to undo any changes made locally and revert to previous saved
values.
Содержание WPoE-2426
Страница 8: ......
Страница 12: ...Publication date August 2012 Revision 1 0 Welltech Technology Co Ltd 2 WPoE 2426 web help function ...
Страница 14: ......