M508 p/n 2M-304456 Owners Manual WV
-2HG
FEATURES & OPERATING CONTROLS (continued)
3
VENTILATOR SECTION
ITEM
DESCRIPTION
COMMENT
1
NAMEPLATE
Gives manufacturer, make and model description. Also lists voltage and amperage
data.
5
APPLIANCE LIGHT
ON
when hood power switch is
ON
. Illuminates cooktop.
a6.
FIRE SUPPRESSION AGENT
TANK (1.5 gal.)
Container for Ansulex™ Low-pH liquid fire suppression liquid.
8
ADJUSTABLE (FRONT) LEG
Allows the unit to be leveled.
9
RIGID (REAR) CASTER
Allows the unit to be easily positioned by lifting the front of the unit slightly.
a10.
MANUAL PULL STATION
Provides a means of manual activation of the fire suppression system. PULL ONLY IN
CASE OF FIRE!
a11.
FUSIBLE LINKS
Designed to break at rated temperature. Breaking (i.e. fire on the cooktop) activates
fire suppression system. Should be replaced at least once per year.
12
LOWER REAR ACCESS PANEL
Allows access to Ansul® fire suppression agent tank (a6) and controls also access to
main power contactor (41).
a15.
DISCHARGE NOZZLE
Fire suppression media discharges here (2 places).
16
GREASE BAFFLE
Extracts and drains most grease and moisture from the air flow.
18
PRE-FILTER ASSEMBLY
Comprises the PRE-FILTER FRAME and a replaceable PRE-FILTER. Stops larger
particles of grease from reaching the FILTER PACK for reduced maintenance costs.
19
HI-EFFICIENCY/CHARCOAL
FILTER PACK
Stops most grease and smoke particles. Also assists in some cooking odor removal.
22
GREASE DRIP TRAY
Collects grease/moisture dripping from grease baffle(16).
28
VENTILATOR EXHAUST DUCT
Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK
a31.
STATUS INDICATOR
Displays status of fire suppression system (
COCKED - FIRED
) If
FIRED
, a buzzer
will sound continuously.
38
POWER CORD
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
41
POWER CONTACTOR
Energizes cooking appliances only while ventilator section is sensed as operational.
42
BUILDING FIRE ALARM RELAY
Reports fire alarm condition to building fire management system.
43
GROUND LUG
Ground wire of power cord connects here.
44
INTERLOCK TERMINAL
Provides connection for shut-down control by building fire management system.
53
FILTER INTERLOCK SWITCHES
Proper installation of grease baffle and filter pack close these switches in ventilator
sensor circuit.
56
VENTILATOR FAN
Provides air movement for ventilation.
57
HOOD SIDE SHIELD
Required on left and right sides of hood. Factory installed.
58
SIDE SPACERS
Required to maintain 6” spacing from combustibles. Field installed