M508 p/n 2M-304456 Owners Manual WV
-2HG
SERVICE TECHNICIAN INSTALLATION NOTES
An Ansul® technician must charge and arm the fire suppression system
before the ventilator blower will operate. See page 11.
Installation and start up must be performed by an Authorized
Installation Company.
Installer must complete the
WARRANTY REGISTRATION
form, and
record appliance installation particulars on the
CUSTOMER SERVICE
DATA
form in this manual.
Certain codes require cooking equipment to be restrained with
a RESTRAINT DEVICE. It is the RESPONSIBILITY OF THE
INSTALLER to check with the authority having jurisdiction, in order
to ascertain the applicability of this requirement to this specific
EQUIPMENT installation. Any restraint device must allow access to
the back and sides of the unit to provide for servicing and maintenance,
and must not interfere with the operation of the FIRE SUPPRESSION
SYSTEM.
ELECTRICAL INSTALLATION
1. This appliance must be installed by a licensed electrician in
accordance with all applicable codes and ordinances.
Electrical connection terminal block and ground lug are accessible
by removing the right side panel.
2. Refer to the nameplate on the right side of the appliance. Verify the
ELECTRICAL SERVICE POWER. Voltage and phase must match
the nameplate specifications, and available electrical service
amperage must meet or exceed the specifications listed on page 1.
Wiring must be no less than 6 AWG solid copper wire, rated for at
least 90ºC.
NOTE:
Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specifications of local codes and of the National
Electrical Code.
NOTE:
This appliance requires a NEMA 15-60R receptacle.
3. This appliance must be connected to a suitable building ground.
The equipment ground connection is marked “ “.
4. The appliance is shipped from the factory wired for 3Ø electrical
service. Refer to the Wiring Diagram included with this appliance,
and verify that field wiring conforms to this diagram.
IMPORTANT: This appliance is not approved for 1Ø operation.
Conversion of this appliance to single-phase operation will void the
warranty.
IMPORTANT!
Verify that this VENTILATOR
and food cooking equipment
installation is in compliance
with the specifications listed
in this manual, with local
code requirements, and in
accordance with N.F.P.A
96 (
THE STANDARD FOR
VENTILATION CONTROL
AND FIRE PROTECTION
OF COMMERCIAL
COOKING OPERATIONS
- current edition).
THIS IS THE
RESPONSIBILITY
OF THE INSTALLER.
DANGER
ELECTRIC
SHOCK
HAZARD
ELECTRIC CONNECTIONS
MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause
death or serious injury.
CAUTION:
ELECTRICAL
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
NOTE: This appliance
requires a dedicated 60
Amp electrical branch circuit
protection.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
INSTALLATION (continued)
10