18
GB
Technical Data
Extraction unit
Laserline 150
MG140
Dimensions L x W x H
340 x 340 x 680 mm
13.4 x 13.4 x 26.8 inch
340 x 340 x 680 mm
13.4 x 13.4 x 26.8 inch
Weight
18 kg
18 kg
Maximum quantity supplied
140 m3/ h (82,3 CFM)
140 m3/ h (82,3 CFM)
Maximum vacuum
2.300 Pa
2.300 Pa
Power consumption
100 W
100 W
Mains supply voltage
110-240 V 50/60 Hz
110-240 V 50/60 Hz
Glass tube fuse (5 x 20)
2 x 6,3 AT, 250 V
2 x 6,3 AT, 250 V
Operating sound level from 1 m distance
< 50 dB(A)
< 50 dB(A)
Combined filter
Combined H13 high
efficiency submicron filter
(99.95 % particle separa-
tion upto 0.12 μm) and
wide band gas filter
(100 % AKF, 50 % Che-
misorb)
Combined H13 high
efficiency submicron filter
(99.95 % particle separa-
tion upto 0.12 μm) and
wide band gas filter
(50% AKF, 50 % Chemi-
sorb)
Interface
The full range of system
functions can be operated
and remotely monitored
via the interface using an
optional interface adaptor.
For remote control
Operation
Put the tool into operation as described in the chapter „Placing into
operation“.
Please adhere to the operating instructions of the connected devices.
Check to see if the mains voltage matches the ratings on the name-
plate.
Make sure the machine is switched off before plugging in.
Optimal gas filtration is achieved as follows:
• Temperature of process air in gas filter < 38 °C
• Relative humidity < 60 %
• Gas molecules > 30 g/mol (better filtration results are achieved
with larger molecules)
• Boiling point of the gas molecules > 0 °C
Caution!
A high noxious gas concent-
ration will cause the activated
charcoal to heat up. To avoid
overheating, the unit should
be run without noxious gases
for several minutes before
switching off.
Notice
The unit may emit dust from
the main filter after transpor-
tation. Make sure that the
unit is put into service in a
suitable room.