62
1. Make sure that network adapter in PC is properly configured. IP address, Subnet mask
and Gateway should be configured at the PC for using Observer II program. Please
contact System administrator to set Unique IP address for the PC.
2. Install Observer II application software in PC. The software may be installed from setup
available in the CD supplied as per the order.
3. Ethernet configuration at Recorder
Please refer to 4.4 Instrument entering IP address, subnet mask and gateway address
manually at the recorder.
Gateway refers to a device on a network that sends local area traffic to other networks.
Subnet mask numbers help to define the relationship between host and rest of the
network.
For every LAN, the Network administrator shall define Subnet mask and Gateway.
Obtain subnet mask and gateway address for the LAN at the place where the recorder to
be connected. Enter these details at the Recorder manually using front buttons.
By default, subnet mask address: 255.255.255.0
By default, Gate way: 0.0.0.0
Allocate the Unique IP address to the recorder and enter IP address at the recorder
manually. Contact System administrator for obtaining free IP address available at user
LAN. Naming duplicate IP address may disable the communication between the recorder
and PC/LAN HUB.
4. Local area network uses UTP cable for Ethernet connectivity. Maximum UTP cable
distance between the recorder and LAN/HUB/PC should be less than 100 Meters. If the
distance is more than 100 Meters, additional LAN accessories/equipments may be
required for increasing signal strength. Please contact network administrator for more
information on extending LAN.
5. Two different types of cables shall be used for connecting the recorder on Ethernet as
follows. For connecting the recorder to LAN HUB, then standard straight-through
Ethernet cable should be used. For connecting the recorder to PC/Notebook directly,
then crossover Ethernet cable should be used.
Straight Through
Cable
VR18-LAN/HUB
Crossover
Cable
VR18-PC/Notebook
RJ-45
PIN
RJ-45
PIN
RJ-45
PIN
RJ-45
PIN
1 Tx+
1 Rc+
1 Rx+
3 Tx+
2 Tx-
2 Rc-
2 Rc-
6 Tx-
Содержание WH18/06
Страница 1: ...User Manual Paperless Recorder WH18 06 15th Edition 03 2008 ...
Страница 17: ...17 Figure 2 6 Figure 2 7 Figure 2 8 ...
Страница 19: ...19 Figure 2 10 Figure 2 11 ...
Страница 25: ...25 Digital input card DI181 Figure 2 21 Analog output card AO183I AO183V Figure 2 22 ...
Страница 26: ...26 24 VDC auxiliary power supply card AP181 Figure 2 23 2 5 RS 232 RS 422 RS 485 wiring Figure 2 24 ...
Страница 27: ...27 Figure 2 25 Figure 2 26 ...
Страница 70: ...70 Make sure that RS 232 communication setting at the recorder and PC are equal ...
Страница 87: ...87 7 Trouble shooting ...
Страница 88: ...88 ...
Страница 89: ...89 ...
Страница 90: ...90 ...