WELL.D MEDICAL WED-3000V Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

WED-3000V

 

 
 

Veterinary Ultrasound Scanner

 

 

User Manual

 

 
 
 
 

 

 

 

 

 

 

 

SHENZHEN WELL.D MEDICAL ELECTRONICS CO. LTD.

 

Содержание WED-3000V

Страница 1: ...WED 3000V Veterinary Ultrasound Scanner User Manual SHENZHEN WELL D MEDICAL ELECTRONICS CO LTD...

Страница 2: ...ly with adapter 12 2 4 2 Battery Operation 12 2 5 Battery charging 13 2 5 1 Charging through main unit 13 2 5 2 Charging through adaptive line 13 2 5 3 Charging through auto charger 14 3 Operating pro...

Страница 3: ...y mark 29 7 Measurement 31 7 1 Ordinary measurement 31 7 1 1 Distance measurement 31 7 1 2 perimeter area measurement 31 7 1 3 Volume measurement 33 7 1 4 M mode measurement 33 7 2 Obstetrics measurem...

Страница 4: ...Ltd assumes the responsibility for equipment security reliability and performance only under the preconditions that the disassembly assembly and maintenance of the equipment are all performed by its...

Страница 5: ...ation or inobservance of the instructions given by manufacturer or its agents may result in equipment damage or personal injury The following convention works through this manual to lay special emphas...

Страница 6: ...nt 4 The patient is prohibited to touch any non applied part of the equipment 5 When operating do not press the keyboard panel too much otherwise the equipment might be damaged After operation 1 Power...

Страница 7: ...osphere pressure range 70KPa 106Kpa Environment requirements on equipment storage and transportation a Environment temperature range 20 55 b Relative humidity range 80 20 7 Do not hit the fragile TFT...

Страница 8: ...or sound output parameters Warning When working in an intensive electromagnetic environment beyond its pre stated one WED 3000V s image may be interfered thus influence the diagnose At this time stop...

Страница 9: ...name sex age hospital annotation Distance circumference area volume and heart rate measurement EDD Measurement for equine bovine sheep dog and cat It offers 16 body marks And Multiple choice probes fo...

Страница 10: ...6 5MHz Rectal C1 11 50R 3 5M Hz convex C1 12 20R 5 0M Hz micro convex 35LV150CP Backfat probe Detect Depth mm 80 140 90 160 Resolution mm Lateral 1 Depth 60 3 Depth 80 5 80 Depth 130 3 Depth 60 2 Dep...

Страница 11: ...16 Image Process Pseudo color GAMA Image Smoothen Histogram Probe Frequency Adjustable 3 point each probe Angle Show Adjustable Measure Distance Circumference area volume Gestational age expected dat...

Страница 12: ...ptional pieces LV2 4 6 5MHz Rectal probe C1 11 50R 3 5MHz convex array probe C1 12 20R 5 0MHz micro convex probe L1 5 7 5MHz HF linear probe Printer CD High speed USB cable Warning Please use the spar...

Страница 13: ...the packing list after uncasing and make sure that there is no shipping damage and then install the equipment according to requirements and methods described in Installation Warning If there is breaka...

Страница 14: ...only one plug jack which is also compatible for those optional probes refer to figure Disassemble probes It is the reverse process of installation Warning Installation and disassembly of the probe mus...

Страница 15: ...l Plug the power cord into the AC input outlet switch on the power switch of the outlet if the DC output indicating light turns on green it works well 4 Shut the power switch of the outlet 5 Insert th...

Страница 16: ...is power on or off the Charging Volume indicator light turns on it means the battery is charged through adapter when the lights turn on it means the battery is fully charged refer to figure Charging t...

Страница 17: ...an arrow of the auto charger to the charging terminal of the battery 3 Plug the other end of the auto charger into the cigar lighter socket 4 When the Charging indicator light on the adapter turns int...

Страница 18: ...t and display the result of volume measurement Right button Determine the start and end position of the cursor and switch the start cursor and end cursor in the distance measurement mode Determine the...

Страница 19: ...can be observed on the screen 5 Freeze the image and conduct measurement on the image 6 Create a report print the report and image by the connected video printer Hospital name probe type Focous focal...

Страница 20: ...mage to B M mode B type and M type real time images can be displayed on the screen at the same time The sample line of B type image can be moved around by mouse and arrow button Press this button agai...

Страница 21: ...e is 27 Press to exit 4 4 Image brightness adjustment Press 7 or 8 button in real time state to lighten B on top right of the screen then press 5 and 6 button to adjust the brightness Press to exit 4...

Страница 22: ...exit the parameter adjustment state on the right of screen Press 5 and 6 button in the B type real time mode to switch the current scanning depth The current depth is displayed on the bottom right of...

Страница 23: ...n press 5 and 6 button to move the focus up and down and change the focal position Press B 0 in turn to exit Tip The focusing of image near the focus indicator is better and you can change the focus n...

Страница 24: ...3 M rate adjustment Press 9 button in real time B M M mode to adjust the refresh rate of M type image on the screen The current scan rate is displayed on the bottom of screen such as ST 2 50S There ar...

Страница 25: ...the cine loop image collection the collect time is about 30 seconds 2 Freeze the image press FUNC 4 0 button in turn to playback and the image is played in a continuous loop The playback state XXX XX...

Страница 26: ...time scanning state The image memory can number the image 01 64 automatically If 01 20 is used it would save from 21 the next time When the memory is full save over 64 images the following dialog box...

Страница 27: ...steps to export other images 5 5 ZOOM At real time or freeze state press FUNC 4 3 button in turn to display or close sampling windows Move sampling window by Mouse or 5 6 7 8 key Press B 0 in turn to...

Страница 28: ...en Move the frame to the interest image area Use 9 and key to adjust the size of the sample frame press to conduct measurement Meanwhile the statistics coordinate and statistics result are displayed o...

Страница 29: ...be restored to the default Press BM 2 to stop the image cleaning 5 11 Report Keep the basic information of current patient hospital doctor explanation in the report page create a report automatically...

Страница 30: ...0 in turn to display the following dialog box 0 A 1 B 2 C 3 D 4 E There are 26 letters and some special characters in the prompt box press 7 8 to page up or down to display other characters Press the...

Страница 31: ...which NAME adapts and the maximum character number is 18 DOCTOR Press 7 in turn to display the following dialog box The input method is the same with the method which NAME adapts and the maximum chara...

Страница 32: ...into interface language switching dialog box Press corresponding number to switch the current language 6 6 Body mark Body mark Press 8 in turn in freeze state and relative body mark could be displayed...

Страница 33: ...30 BOVINE EQUINE...

Страница 34: ...original data would be overwritten The current measure result would be displayed on the right of screen The distance rate is listed as D1 D2 D3 D4 Press B 0 to clear the measurement mark and measurem...

Страница 35: ...choose elliptical method and the elliptical sample frame is displayed on the screen 5 Move sample frame to measure area 6 Press or right button of mouse adjust the size by direction button 7 Press or...

Страница 36: ...B M mode 2 Measure the distance of two ridges of periodic waves by distance measurement method Date of 3 groups is displayed at the right of screen which is listed from up to down heart rate unit n m...

Страница 37: ...listed as following EQUINE GSD Calculate the gestation age according to horse GS Examination steps on equine 1 Clear off the egesta in rectum 2 Feel the pregnancy with hand and give a primary estimat...

Страница 38: ...BL Examination steps on bovine 1 Clear off the egesta in rectum 2 Feel the pregnancy with hand and give a primary estimation and confirm the examing organ with ultrasound 3 Hold the probe closely and...

Страница 39: ...e measurement methods and the corresponding data display behind G A 7 BOVINE SL Calculate the gestation age according to bovine SL 1 Keep the cow standing 2 Put the probe against the abdomen side cent...

Страница 40: ...mum vertical axile of the heart should be displayed on the screen With the time going on futus heart long axile increases regularly The measuremenet method is given below 4 Confrim the distance value...

Страница 41: ...o methods to exam pregnant sheep Use convex or linear probe to check abdomen and endo rectal probe to rectum These two methods are the same usful It is proofed as cording to some publication that thes...

Страница 42: ...cat BD After fetal head formed binary top diameter measurement becomes a routine in ultrasonic examination The measuring method is 1 Fetal head axial plane scanning look for BPD measuring standard pl...

Страница 43: ...n the distance is less than the following value the GA of this animal will not display Refer to the following table for detailed data EQUINE D1 6mm BOVINE BL D1 8mm BOVINE SL D1 1mm BOVINE HL D1 3mm S...

Страница 44: ...ng shutdown the device first and then wipe with alcohol sponges Device should not turn on and off frequently When the device does not work for a long time pack the device according to the instructions...

Страница 45: ...ensure it is good incase liquid ingression spoil the inner components R50 3 5MHz L40 7 5MHz R20 5 0MHz 35LV150CP Backfat probe Probe and host machine once tie be request not to take down at will for...

Страница 46: ...probe cleaning Never use the probe again if any crack or breakage is found 8 5 Battery information 1 The equipment is fitted with rechargeable li ion battery 2 For optimum efficiency the new battery...

Страница 47: ...cket 14 Must not short circuit the positive and negative polarity of the battery with led or other metal objects Must not transport nor store the battery with necklace hair pin or other metal objects...

Страница 48: ...lace the damaged or broken one if found 9 2 Simple trouble shooting S N Simple failure Solutions 1 When power on PS indicator light does not turn on and no display on screen 1 Check if 14V of adapter...

Страница 49: ...ckproof establishment is fitted within the box which apply to aviation railway highway or steamship transportation Keep dry avoid inversion and collision 10 3 Storage Equipment should be taken out fro...

Страница 50: ...lic uses 3 Information on MI and TI need not be provided if the equipment meets both exemption clauses given in 51 2 aa and 51 2 dd Index label MI TIS TIB TIC Scan Non scan Non scan Aaprt 1cm2 Aaprt 1...

Страница 51: ...ic uses 3 Information on MI and TI need not be provided if the equipment meets both exemption clauses given in 51 2 aa and 51 2 dd Index label MI TIS TIB TIC Scan Non scan Non scan Aaprt 1cm2 Aaprt 1c...

Страница 52: ...lic uses 3 Information on MI and TI need not be provided if the equipment meets both exemption clauses given in 51 2 aa and 51 2 dd Index label MI TIS TIB TIC Scan Non scan Non scan Aaprt 1cm2 Aaprt 1...

Страница 53: ...ephalic uses 3 Information on MI and TI need not be provided if the equipment meets both exemption clauses given in 51 2 aa and 51 2 dd Index label MI TIS TIB TIC Scan Non scan Non scan Aaprt 1cm2 Aap...

Страница 54: ...Equine Measurement mm Week Day Gestational Sac Diameter 6 1 4 8 1 4 10 1 5 12 1 6 14 1 6 16 2 0 18 2 0 20 2 1 22 2 2 24 2 3 26 2 5 28 4 1 30 4 2 32 4 3 34 4 4 40 5 0 42 5 2 44 5 3 46 5 4 48 5 5 50 5 6...

Страница 55: ...52 Gestational Table 2 Bovine Measurement mm Week Day Body Length 8 4 0 10 5 0 12 5 1 14 5 2 16 5 3 18 5 5 20 5 5 22 5 6 24 5 6 26 6 1 28 6 1 30 6 1 32 6 2 34 6 3 36 6 3 All measurements 3 days...

Страница 56: ...o Spine Distance 15 7 1 18 7 3 21 7 6 24 8 1 27 8 4 30 9 0 33 9 2 36 9 4 39 10 0 42 10 2 45 10 5 48 11 3 51 11 5 54 12 1 57 12 2 60 12 4 63 12 6 66 13 2 69 13 4 72 14 2 75 14 4 78 15 0 81 15 2 84 15 5...

Страница 57: ...Well d Park Qinglan 3 Rd National Biopharmaceutical Industrial Base Pingshan New Area Shenzhen 518118 China Tel 0086 755 36900018 36900019 36900020 Fax 0086 755 36900018 Http www welld com cn www well...