3.11.
CAN
CAN Network 구성을 위하여 디바이스의 종단에 120옴의 저항을 연결
- For CAN network configuration, a resistor of 120 ohms to the terminal of the device.
[CAN Communication]
Fieldbus Type
Product Number
CAN
WEM-D048xx-FSxxxx-
EC
Molex_505565_0301
Molex 5054311000
MOLEX 505567-0371
J8, J9
Pin
Signal
1
HIGH
2
LOW
3
GND