![Welbilt Merrychef microMD UK Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/welbilt/merrychef-micromd-uk/merrychef-micromd-uk_service-manual_953839015.webp)
15
Microwave service manual – Model:
microMD UK
Components
Test procedure
Results
Note: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
High voltage capacitor
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal
Normal: Momentarily
indicates several ohms,
and then gradually
returns to 10M ohms
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case
Normal: ∞
High voltage diode
Note: Some inexpensive
meters may indicate infinite
resistance in both direction.
Measure the continuity (Forward)
(Ohm-meter scale: Rx10000)
Normal: Continuity
Abnormal: ∞ *
Measure the continuity (Reverse)
(Ohm-meter scale: Rx10000)
Normal: ∞
Abnormal: Continuity
Antenna
Gasket
Chassis
Filament