microMD UK
Components test procedure
Cautions:
1. Disconnect the power supply cord from the outlet whenever removing the outer
case from the unit. Proceed with the test only after discharging the high voltage
capacitor and removing the wire leads from the primary winding of the high voltage
transformer. (See page
x-x
)
2. All operational checks with microwave energy must be done with a load (1 litre of
water in container) in the oven.
Components
Test procedure
Results
High voltage transformer
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Primary winding
• Secondary
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
Approx: 1.4 ohm
Approx: 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Magnetron
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
WINDING
FILAMENT
WINDING
TERMINAL