4.2.2 Installation on a flat roof (optional)
Observe wind load in accordance with DIN 1055 and protect depending on structural
conditions on site.
Weishaupt recommends mounting rails (accessory) for installation on a flat roof.
▶
Fit mounting rails
1
to the roof.
▶
Place unit on to the mounting rails and align horizontally.
▶
Secure unit to the mounting rails using the 4 screws
2
provided.
▶
Specify on which side the electrical wiring and refrigerant pipework should be
routed.
▶
Break out pre-cut break point using a screwdriver.
▶
Deburr the opening and fit edge protection supplied.
Installation and operating instruction
Outdoor unit WWP L 15 ARS
4 Installation
83292002 • 1/2014-05 • La
25-55
Содержание WWP L 15 ARS
Страница 1: ...Installation and operating instruction Outdoor unit WWP L 15 ARS 83292002 1 2014 05 ...
Страница 52: ...12 Notes Installation and operating instruction Outdoor unit WWP L 15 ARS 12 Notes 83292002 1 2014 05 La 52 55 ...