4 Installation
4.1 Installation conditions
Installation location
The air flow in the intake and outlet area must not be impeded.
▶
In areas with heavy snow fall the unit should be installed at a higher elevation or
where it is protected from snow.
▶
Ensure intake area is kept free from leaves.
Cooled outlet air can lead to cooling of adjacent heated rooms and to icing up of
footpaths, drainpipes, etc.
▶
Do not direct outlet air towards walls, footpaths or drainpipes.
Cooled air collects at low level and in courtyards and is drawn in again by the heat
pump.
▶
Do not install the unit at low level or in courtyards.
The height difference between the outdoor unit and the hydraulic unit must not ex-
ceed 10 m.
In areas with strong wind, the unit should be installed in such a way that the wind
does not blow directly toward the fan.
▶
Check the main wind direction.
Sound can be amplified when it is reflected by walls. Installation in wall niches and in
wall corners adversely affect the sound emissions.
▶
The unit should preferably be installed in an open area.
Observe requirements of TA Noise relative to noise emissions (see Ch. 3.4.5). For
example distance to bedrooms, terraces, etc.
Installation and operating instruction
Outdoor unit WWP L 15 ARS
4 Installation
83292002 • 1/2014-05 • La
21-55
Содержание WWP L 15 ARS
Страница 1: ...Installation and operating instruction Outdoor unit WWP L 15 ARS 83292002 1 2014 05 ...
Страница 52: ...12 Notes Installation and operating instruction Outdoor unit WWP L 15 ARS 12 Notes 83292002 1 2014 05 La 52 55 ...
Страница 53: ...Installation and operating instruction Outdoor unit WWP L 15 ARS 12 Notes 83292002 1 2014 05 La 53 55 ...