4.2.1 Floor mounted installation
The outdoor unit must have a minimum clearance of 10 cm from the floor and must
be installed at least 20 cm above any expected snow level.
Weishaupt recommends a strip foundation (see Ch. 11.1).
▶
Place unit on to the floor or foundation and align horizontally.
✓
Condensate can seep into the gravel.
▶
Specify on which side the electrical wiring and refrigerant pipework should be
routed.
▶
Secure unit to floor using M8 screws
1
.
▶
Break out pre-cut break point using a screwdriver.
▶
Deburr the opening and fit edge protection supplied.
Installation and operating instruction
Outdoor unit WWP L 15 ARS
4 Installation
83292002 • 1/2014-05 • La
24-55