Installation and operation instructions
Separation station WHI sol/heat 20 #1 / 40 #1; Separation station WHI sol/aqua 20 #1 / 40 #1
3 Product description
83514202
▪
1/2014-06
▪
Ext. PAW
12-36
3.3
Technical Data Pumps
UPM2
15-75 CIL
Solar PM2
15-65
Solar PM2
15-145
Solar PML
25-145
UPM GEO
25-85
UPML GEO
25-105 N
Length
130 mm
180 mm
Connections
1" male thread
1½" male thread
Protection class
IP 44
Max. pressure
1.0 MPa (= 10 bars)
Max. temperature
95 °C TF 95
I (1/1)
0.04-0.52 A
0.04-0.40 A
0.06-0.68 A
0.07-1.16 A
0.06-0.71 A
0.06-1.16 A
P1
3-70 W
3.5-48 W
7-69 W
6-140 W
5-87 W
6-140 W
Use in:
WHI sol/heat 20 #1
Sec
Prim
WHI sol/aqua 20 #1
Sec
Prim
WHI sol/heat 40 #1
Prim
Sec
WHI sol/aqua 40 #1
Prim
Sec
Prim = primary side (solar) / Sec = secondary side (heating / potable water)
3.4
PWM input signal (solar profile)
PWM input signal
[%]
Pump status
< 6
Standby
6-8
Hysterese
9-15
Min. speed
16-90
Linear increase in
speed from rpm
min. to rpm max.
91-100
Max. speed
S
pee
d
PWM input signal [%]
Min.
Stop
Max
.
Содержание WHI sol/aqua 20 1