![Weishaupt WG20 1-C Z-LN Series Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/weishaupt/wg20-1-c-z-ln-series/wg20-1-c-z-ln-series_manual_953344019.webp)
Installation and operating instruction
Gas burner WG40…/1-A ZM-LN
3 Product description
83300002 1/2019-02 La
19-128
3.4.6 Rating
Combustion heat rating
Natural Gas
Liquid Petroleum Gas
55 … 550 kW
80 … 550 kW
Combustion head
WG40/1-LN
Capacity graph
Capacity graph to EN 676.
The capacity data given relates to an installation elevation of 0 m above sea level.
For installation elevations above 0 m a capacity reduction of
approx. 1 % per 100 m applies.
A limited capacity graph is valid for ducted air intake.
Combustion heat rating at combustion head setting:
Natural Gas
Liquid Petroleum Gas
Combustion head OPEN
3
5
Combustion head CLOSED
4
6
5
4
6
3
1
2
-2
-3
-1
0
1
2
3
4
600
550
400
350
300
250
200
150
100
50
0
5
6
7
8
500
450
1
Combustion heat rating [kW]
2
Combustion chamber pressure [mbar]