39 of 44
Document P/N:
2P137414
Release Date:
05/29/2017
Revision: IR
SPM
®
QWS 2500 Grooved and Grooveless Fluid End Removal:
1.
Remove the plunger clamps and separate each plunger from each pony rod as outlined earlier in
“To Change Plungers and Packing”.
2.
Disconnect the plunger lube hoses and whatever discharge piping connections and suction piping
connections are necessary for fluid end removal.
3.
Using a 2¾” wrench, remove the twenty 1¾” nuts which secure the fluid cylinder to the power end
stay rods. Remove the fluid cylinder from the power end and set fluid end on pallet upright.
4. Inspect the face of the fluid cylinder for wear or fretting around the stay rod holes. Inspect the
shoulders of the stay rods for wear or cracks. Check all twenty stay rod nuts for the correct torque
(1000 ft. lbs. with lubricated threads) prior to reinstalling the fluid cylinder. For fluid end installation
procedure, refer to the
SPM
®
QWS 2500 Fluid End operation instruction and service manual
(SPM
®
document 2P136539).
Содержание SPM QWS 2500 XL
Страница 12: ...12 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR Performance Data ...
Страница 13: ...13 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 14: ...14 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 15: ...15 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 16: ...16 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 17: ...17 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 18: ...18 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 22: ...22 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 23: ...23 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR ...
Страница 28: ...28 of 44 Document P N 2P137414 Release Date 05 29 2017 Revision IR Power End Lube System Schematic ...