START-UP
WARNING
ALL GUARDS AND PROTECTIVE DEVICES MUST BE INSTALLED BEFORE
THE PUMP IS STARTED. CONTACT WITH UNGUARDED BELTS, SHEAVES,
OR COUPLINGS COULD RESULT IN INJURY.
DO NOT OPERATE PUMP WITH BOTH SUCTION AND DISCHARGE VALVES
CLOSED OR WITH SUCTION OR DISCHARGE CLOSED BY CLOGGING. THIS
COULD CAUSE DAMAGE AND IS DANGEROUS. ROTO-JET PUMPS ARE TO
BE USED FOR LIQUID SERVICE ONLY. EXCESS PRESSURE CAN CAUSE
MALFUNTION LEADING TO INJURY.
1.
Start driver and bring unit up to speed.
2.
Slowly open discharge valve until operating point is reached.
3.
Check bearings during first hour of operation to be sure that they are operating
correctly. (Bearing temperatures should not exceed 180° F (82° C) for ambient
pumping temperatures.)
E.
OPERATING CHECKS
1.
Check the pump and piping to assure that there are no leaks.
2.
Check and record inlet and discharge pressure gauge readings for future
reference.
3.
Check and record voltage, amperage per phase and KW if an indicating
wattmeter is available.
4.
Note any unusual noise or vibration.
F.
OPERATING CAUTIONS
1.
Belt and coupling guards must always be in place during operation.
2.
In cold weather, the fluid in the pump and piping must be kept from freezing.
3.
The pump must always be primed before starting or the mechanical seal may
be damaged.
4.
Repeated trial starts may overheat the driver; allow sufficient time between
starts for heat to dissipate from motor windings.
5.
The pump must always be operated within its design limits.