Notes on the assembly and installation instructions 

1.1  Qualifications 

These instructions are intended for weinor retailers and partners and assume relevant 

knowledge. All installation work must be performed by a trained electrician.  

 

1.2  Notes on remote control units 

  Remote control units transmitting on the same frequency may disrupt reception. 

  The range of the transmitted signal is restricted by law and structural measures. 

 

1.3  Depiction 

  Warnings 

1.3.1

The warnings differentiate between personal injury and damage to property. The signal word 

"Danger" is used for personal injury, and "Caution" for property damage. 

 

 

Immediate danger to life and limb! 

 

Immediate danger to the product and environment! 

 

  Tips and recommendations 

1.3.2

 

Highlights useful tips and information that enable quick and correct assembly. 

 

 

  Illustrations 

1.3.3

Notes on item numbers can be found in the text in parentheses, e.g. 

(1)

.  

 

  Instructions requiring action 

1.3.4

Instructions requiring action are written in bold print. If the instruction requiring action consists of 

several individual steps, these are numbered in the order in which they are to be carried out. 

 

Example: 

1. 

Getting started 

 

 

  Press the Program key. 

1.

 

 

  Press the Learn key. 

2.

 

 

 

DANGER 

CAUTION 

Содержание BiRec MA

Страница 1: ...ISH FRAN AIS BiRec MA BiRec MA K Please read these instructions and observe their contents and warnings before commencing any assembly work This information is critical to the installation and the pro...

Страница 2: ...s 3 1 3 4 Instructions requiring action 3 2 Safety notes 4 2 1 Fundamental safety notes 4 2 2 Electricity hazards 4 2 3 Intended use 4 2 4 Improper use 4 3 Description of device 5 3 1 Summary of devic...

Страница 3: ...d signal is restricted by law and structural measures 1 3 Depiction Warnings 1 3 1 The warnings differentiate between personal injury and damage to property The signal word Danger is used for personal...

Страница 4: ...weinor 2 2 Electricity hazards Work involving connections to 230 V mains may only be carried out by a trained electrician Disconnect the unit from the power supply before performing any work weinor r...

Страница 5: ...e de modifications techniques Num ro d article 117476 0000 Page 5 28 3 Description of device 3 1 Summary of device components Figure1 BiRec MA remote receiver Figure 2 BiRec MA K remote receiver Item...

Страница 6: ...BiRec MA K remote receiver includes a short lead approx 0 2 m long and an integrated STAS3 Hirschmann connector Connector pin assignment 3 2 2 The following connector pin assignment is used see figure...

Страница 7: ...he hand transmitter channel see the hand transmitter operating instructions The BiRec MA MA K remote receiver has been pre set in the factory to perform the following functions when used together with...

Страница 8: ...cing has been carried out however the system will need to be programmed on site This is done by pairing up the hand transmitter and remote receiver see Section 6 4 3 Checking the functions Once all th...

Страница 9: ...r was last exceeded BiSens Agido 3V product protection sensor has been triggered in last few minutes The device unlocks automatically after 15 20 minutes Programmed sun wind or sun wind rain sensor is...

Страница 10: ...down the LEARN key 1 on the hand transmitter for 2 seconds The remote receiver then enters programming mode for about 2 minutes During this time the awning moves up for 4 seconds and then down for 4...

Страница 11: ...ous reserve de modifications techniques Num ro d article 117476 0000 Page 11 28 6 3 Deleting the remote receiver To delete individual transmitters from the receiver Hold down the STOP key and LEARN ke...

Страница 12: ...30 V mains may only be carried out by a trained electrician Disconnect the unit from the power supply before performing any work 7 1 Maintaining the remote receiver It is not possible to carry out rep...

Страница 13: ...5 m cable with bare ends Awning motor input STAK3 Hirschmann connector integrated Awning switching method Awning runs on self sustaining power until end position is recognized max 120 sec Compatibili...

Страница 14: ...ratoires 15 2 Instructions de s curit 16 2 1 Consignes de s curit fondamentales 16 2 2 Dangers relatifs l lectricit 16 2 3 Utilisation conforme 16 2 4 Utilisation abusive 16 3 Description de l appare...

Страница 15: ...entions de mise en page Avertissements 1 3 1 Les avertissements sont diff renci s selon qu ils concernent des dommages en lien avec des personnes ou des biens mat riels En cas de dommages aux personne...

Страница 16: ...ils autoris s par weinor 2 2 Dangers relatifs l lectricit Les raccordements au r seau 230 V doivent uniquement tre effectu s par un lectricien Avant d effectuer tous travaux mettre l installation hors...

Страница 17: ...odifications techniques Num ro d article 117476 0000 Page 17 28 3 Description de l appareil 3 1 Vue d ensemble de l appareil Illustration 2 r cepteur radio BiRec MA Illustration 2 r cepteur radio BiRe...

Страница 18: ...e 0 2 m avec un connecteur Hirschmann STAS3 int gr e Affectation des connecteurs 3 2 2 L affectation des connecteurs suivante est utilis e pour les d tails voir illustration 1 C ble r seau de 5 m extr...

Страница 19: ...l de l metteur manuel voir instructions d utilisation de l metteur manuel la livraison le r cepteur radio BiRec MA MA K en lien avec un metteur manuel commande les fonctions suivantes Canal 1 store Le...

Страница 20: ...el et le r cepteur radio sont affect s l un l autre voir chapitre 6 4 3 V rification des fonctions Une fois l installation enti rement achev e vous devez contr ler que le syst me fonctionne correcteme...

Страница 21: ...ur seuil du vent Le capteur de protection du produit BiSens Agido 3V s est d clench au cours des derni res minutes Le verrouillage de la commande se d bloque automatiquement au bout de 15 20 minutes L...

Страница 22: ...trouve en mode de param trage dans lequel la tenture rentre pendant 4 secondes puis ressort pendant 4 secondes 3 l aide de l metteur manuel s lectionnez le canal sur lequel le store doit tre param tr...

Страница 23: ...techniques Num ro d article 117476 0000 Page 23 28 6 3 D sactiver le r cepteur radio D sactiver un seul metteur du r cepteur Maintenir simultan ment enfonc es la touche ARR T et la touche PARAM TRAGE...

Страница 24: ...doivent uniquement tre effectu s par un lectricien Avant d effectuer tous travaux mettre l installation hors tension 7 1 Effectuer la maintenance du r cepteur radio Le r cepteur radio lui m me ne peu...

Страница 25: ...le extr mit s ouvertes Raccordement au moteur store Connecteur Hirschmann STAK3 int gr Proc d de commutation Store Store auto maintien jusqu la d tection de la position de fin de course 120 sec max Co...

Страница 26: ...our website At http www weinor com service downloads eu declaration of conformity Disposal For the disposal of the device the currently applicable international national and regional laws and directi...

Страница 27: ...ation de conformite ue Gestion des d chets Pour la mise au rebut de l appareil il convient de respecter les r glementations et directives r gionales nationales et internationales en vigueur au moment...

Страница 28: ...instructions Instructions de montage et d installation Item number We reserve the right to make technical changes Sous reserve de modifications techniques Num ro d article 117476 0000 Page 28 28 weino...

Отзывы: