Part number 550-100-261/0520
5
ECO
®
Tec
G
as
-
fired
water
boiler
– 80/110/150/199 U
ser
’
s
i
nformation
m
anUal
OWNER MAINTENANCE
(see the following pages for instructions)
BEGINNING OF SEASON
Contact your boiler service technician to inspect, service
and start up your boiler.
You must have an annual start-up
performed by a qualified service technician
to ensure reliable
operation of the boiler and system.
DAILY
•
Check boiler area.
•
Check air openings.
•
Check pressure/temperature gauge.
•
Verify boiler jacket door is securely closed.
MONTHLY
•
Check vent piping.
•
Check air piping.
•
Check relief valve.
• Verify that domestic hot water is being supplied to fixtures at the
correct temperature.
•
Check condensate drain system.
•
Check automatic air vents (if used).
•
Check display date and time.
EVERY 6 MONTHS
•
Check boiler piping (gas and water).
•
Operate relief valve.
Follow the service and maintenance procedures given throughout this manual and in component literature
shipped with the boiler. Failure to perform the service and maintenance could result in damage to the boiler or
system. Failure to follow the directions in this manual and component literature could result in severe personal
injury, death or substantial property damage.
Figure 2
Service and maintenance schedules
Annual startup and general maintenance