上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
24
/
61
2. Set
Setting
in the upper left corner to
ON
.
3. In the
Basic Setting
area, click the
Active Tool
pull-down menu, select the target
tool number, and set the following parameters:
o
Positioning Times:
Indicates the times of fine positioning when approaching
the tool sensor during tool calibration.
o
Positioning Speed:
Indicates the speed when approaching the tool sensor
during tool calibration.
4. In the
Fixed tool setter coordinate 1
area, set the parameters of the fixed tool
sensor:
o
X FixedPoint
: X-axis mechanical coordinate of the fixed tool sensor
o
Y FixedPoint:
Y-axis mechanical coordinate of the fixed tool sensor
o
Z FixedPoint:
Z-axis mechanical coordinate of the fixed tool sensor
o
LowestPoint
: Mechanical coordinate of the Z-axis lowest point during tool
calibration.
5. Select one from the following tool calibration methods:
o
Fixed calibration
o
First-time calibration/Calibration after tool change
o
Mobile calibration
3.7.4.1 Fixed Calibration
If a tool is replaced due to being broke or other reasons, the length of the new tool and
where the new tool is clamped may be different from the replaced one. In this case, fixed
calibration can be used to measure the length of the new tool from a fixed position of the
machine and determine the tool offset for better machining accuracy. Fixed calibration is
applicable to machine with a tool magazine.
Before executing fixed calibration, set the manufacturer parameter
Tool Calibration Type
to
1
.
Follow the steps below to execute fixed calibration: