background image

Panel Layout of 
IE-MC-VL Series 

 
1. Grounding 

screw 

2. 

Terminal block for power 
input PWR1/PWR2 and 
relay output 

3. 

Heat dissipation orifices 

4. Dip 

switch 

5. 

Power input PWR1 LED 

6. 

Power input PWR2 LED 

7. Fault 

LED 

8. 100BaseFX 

(ST 

connector) 

Port 

9. 

FX port’s 100 Mbps LED 

10.  FX port’s Full 

Duplex/Collision LED 

11.  TP port’s 100 Mbps LED 
12. 10/100BaseT(X) 
13.  TP port’s 10 Mbps LED 
14. Article 

Number 

15. 100BaseFX 

(SC 

connector) 

Port 

16.  Screw hole for wall mounting kit
17.  DIN-Rail mounting kit 

Front Panel View 

IE-MC-VL-1TX-1ST 

Front Panel View 

IE-MC-VL-1TX-1SC/1SCS

Top Panel View 

Rear Panel View 

 

- 3 -

Содержание IE-MC-VL

Страница 1: ...43430000 02 06 11 Please note This document and any further product information if available can be downloaded at the internet link http www weidmueller com downloads Copyright Notice Copyright 2011 W...

Страница 2: ...uring that your Ethernet equipment can withstand critical industrial applications such as in hazardous locations Class 1 Division 2 Zone 2 and complies with FCC T V UL and CE Standards Package Checkli...

Страница 3: ...LED 7 Fault LED 8 100BaseFX ST connector Port 9 FX port s 100 Mbps LED 10 FX port s Full Duplex Collision LED 11 TP port s 100 Mbps LED 12 10 100BaseT X 13 TP port s 10 Mbps LED 14 Article Number 15 1...

Страница 4: ...en you take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Inse...

Страница 5: ...ect locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NOTE Test the scr...

Страница 6: ...either in external to the apparatus to prevent the rated voltage being exceeded by the transient disturbances of more than 40 Wiring Requirements WARNING Do not disconnect modules or wires unless pow...

Страница 7: ...verheat causing serious damage to your equipment You should also pay attention to the following points y Use separate paths to route wiring for power and devices If power wiring and device wiring path...

Страница 8: ...cts form an open circuit when 1 The Media Converter has lost power from one of the DC power inputs OR 2 One of the ports for which the corresponding PORT ALARM Dip Switch is set to ON is not properly...

Страница 9: ...Tx Rx Rx 1 8 Pin Signal 1 2 3 6 Rx Rx Tx Tx RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx NIC Port...

Страница 10: ...rter has one Alarm Contact located on the top panel For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6 contact terminal block connector see t...

Страница 11: ...ont panel of the Media Converter contains several LED indicators The function of each LED is described in the table below LED Color State Description On Power is being supplied to power input PWR1 PWR...

Страница 12: ...es All models of Weidm ller Media Converter are plug and play devices so that software configuration is not required at installation or during maintenance The half full duplex mode for the RJ45 switch...

Страница 13: ...capacity of 1A 24 VDC Optical Fiber Multi mode Single mode Distance 5 km 40 km Wavelength 1310 nm 1310 nm Min TX Output 20 dBm 5 dBm Max TX Output 14 dBm 0 dBm Sensitivity 34 to 30 dBm 36 to 32 dBm R...

Страница 14: ...will be repaired by Weidm ller free of charge or that Weidm ller will provide a new functionally equivalent product to replace the defective one Safe where expressly described otherwise in writing in...

Отзывы: