Dip Switch Setting 

IE-MC-VL Series DIP switch

 

1 2 3

ON      DIP

 

Dip Switch 1 (Default: Off ) 

ON

: Enables the PORT Alarm. If the port’s link fails, 

the relay will form an open circuit and the fault 
LED will light up. 

Off

: Disables the corresponding PORT Alarm. The 

relay will form a closed circuit and the Fault 
LED will never light up. 

Dip Switch 2 (Default: ON ) 

ON

: Enables full duplex for 100BaseFX 

Off

: Disables full duplex for 100BaseFX 

Dip Switch 3

 

Reserved for future use 

To activate the updated DIP switch settings, power off and then 
power on the Media Converter. 

 

LED Indicators 

The front panel of the Media Converter contains several LED 
indicators. The function of each LED is described in the table below. 

LED 

Color 

State 

Description 

On 

Power is being supplied to 

power input PWR1 

PWR1 

AMBER 

Off 

Power is 

not

 being supplied 

to power input PWR1 

On 

Power is being supplied to 

power input PWR2 

PWR2 

AMBER 

Off 

Power is 

not

 being supplied 

to power input PWR2 

On 

When the corresponding 

PORT alarm is enabled, 

and the port’s link is 

inactive. 

FAULT 

RED 

Off 

When the corresponding 

PORT alarm is enabled and 

the port’s link is active, or 

when the corresponding 

PORT alarm is disabled. 

On 

TP port’s 10 Mbps link is 

active 

Blinking 

Data is being transmitted at 

10 Mbps 

10M 

GREEN 

Off 

TP Port’s 10 Mbps link is 

inactive 

100M 

GREEN 

On 

TP port’s 100 Mbps link is 

active 

 

- 11 -

Содержание IE-MC-VL

Страница 1: ...43430000 02 06 11 Please note This document and any further product information if available can be downloaded at the internet link http www weidmueller com downloads Copyright Notice Copyright 2011 W...

Страница 2: ...uring that your Ethernet equipment can withstand critical industrial applications such as in hazardous locations Class 1 Division 2 Zone 2 and complies with FCC T V UL and CE Standards Package Checkli...

Страница 3: ...LED 7 Fault LED 8 100BaseFX ST connector Port 9 FX port s 100 Mbps LED 10 FX port s Full Duplex Collision LED 11 TP port s 100 Mbps LED 12 10 100BaseT X 13 TP port s 10 Mbps LED 14 Article Number 15 1...

Страница 4: ...en you take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Inse...

Страница 5: ...ect locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NOTE Test the scr...

Страница 6: ...either in external to the apparatus to prevent the rated voltage being exceeded by the transient disturbances of more than 40 Wiring Requirements WARNING Do not disconnect modules or wires unless pow...

Страница 7: ...verheat causing serious damage to your equipment You should also pay attention to the following points y Use separate paths to route wiring for power and devices If power wiring and device wiring path...

Страница 8: ...cts form an open circuit when 1 The Media Converter has lost power from one of the DC power inputs OR 2 One of the ports for which the corresponding PORT ALARM Dip Switch is set to ON is not properly...

Страница 9: ...Tx Rx Rx 1 8 Pin Signal 1 2 3 6 Rx Rx Tx Tx RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx NIC Port...

Страница 10: ...rter has one Alarm Contact located on the top panel For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6 contact terminal block connector see t...

Страница 11: ...ont panel of the Media Converter contains several LED indicators The function of each LED is described in the table below LED Color State Description On Power is being supplied to power input PWR1 PWR...

Страница 12: ...es All models of Weidm ller Media Converter are plug and play devices so that software configuration is not required at installation or during maintenance The half full duplex mode for the RJ45 switch...

Страница 13: ...capacity of 1A 24 VDC Optical Fiber Multi mode Single mode Distance 5 km 40 km Wavelength 1310 nm 1310 nm Min TX Output 20 dBm 5 dBm Max TX Output 14 dBm 0 dBm Sensitivity 34 to 30 dBm 36 to 32 dBm R...

Страница 14: ...will be repaired by Weidm ller free of charge or that Weidm ller will provide a new functionally equivalent product to replace the defective one Safe where expressly described otherwise in writing in...

Отзывы: