background image

Stripping and crimping machine 

 

Crimpfix 2.5 M  

08-09-19-DK-Operating Manual_gb.doc / 2008-09-19

  

1. 

Terms of use 

Please read carefully through this manual and observe the notes and explanations. Only by carefully following 
these instructions the proper and trouble free operation of the Crimpfix 2.5 M machine can be guaranteed. 
 
These operating instructions have been written with due care and attention. However, unless otherwise required 
by law, we do not guarantee that the data, images and drawings are accurate or complete nor do we accept 
liability for their contents. Weidmüller’s general terms and conditions of sale apply in their respective valid form. 
Subject to alteration without notice 
 
 
 
 

2. Prescribed 

use 

This device is intended for use in applications only as described in the operating instructions. Any other form of 
usage is not permitted and can lead to accidents or destruction of the device. Using the machine in non-
approved applications will lead immediately to the expiration of all guarantee and warranty claims on the part of 
the operator against the manufacturer. 
 
Using the selected machine for purposes other than those specified or failure to observe the operating 
instructions and warning notes can lead to serious malfunctions that may result in personal injury or damage to 
property. 
 
Stripping of insulated wires according to 

DIN VDE 0295/class 5 

 DIN 

VDE 

0281/102 

 DIN 

VDE 

0281/103 

 
Cross-section  

0.5 – 2.5 mm² 

 0.34 

mm² 

 

optional 

 
Feeding-length   

40 mm 

 
Crimping of Weidmüller ferrules on reel with insulating collar: 
 
  

0,34/12 

optional 

 H 

0,5/14 

 H 

0,75/14 

 H 

1,0/14 

 H 

1,5/14 

 H 

2,5/14 

 

Crimpform 

 

Trapez-Indent 

 
The use of ferrules type H 0.34/12 is only possible with the 0.34 tooling set. 
 
 
The indented use includes also the observance of all information in the operating manual and the compliance of 
the maintenance work. (See chapter 10) 
 
 

Содержание Crimpfix 2.5 M

Страница 1: ...Weidm ller Interface GmbH Co Klingenbergstra e 16 D 32758 Detmold Telefax 05231 14 0 Telefon 05231 14 20 83 Operating Manual Stripping and crimping machine Crimpfix 2 5 M Fabrication number...

Страница 2: ...8 7 1 Putting into operation 8 7 2 Starting the machine 8 7 3 Inserting ferrules 8 7 4 Changing the ferrule belt 9 7 5 Adjustment of the cross section 9 7 6 Control of the stripping quality 9 7 7 Wir...

Страница 3: ...f usage is not permitted and can lead to accidents or destruction of the device Using the machine in non approved applications will lead immediately to the expiration of all guarantee and warranty cla...

Страница 4: ...vals such as photocopiers or fans Do not connect the Crimpfix 2 5 M to either a switched or a time controlled plug socket outlet Never use damaged or scuffed power cables If you connect the Crimpfix 2...

Страница 5: ...ety and accident prevention To take care that all safety and danger indications are clearly visible replace them if necessary To inform the manufacturer immediately if the machine and the application...

Страница 6: ...ine filter 2 x T2AH250V Protecting class IP20 Cycle time 1 5 s Continuous sound level 70 dB A Dimensions w x d x h without reel and holder 292 x 310 x 260 mm Colour RAL 7021 Weight 15 kg Temperature O...

Страница 7: ...6 General view of the machine Figure 1 Front view Figure 2 Back view Mains switch Reel holder Fuse Flap Mains plug Stripping waste container Flap Feeding funnel Reel holder Stripping waste container...

Страница 8: ...rules Open the flap Release the locking pin see Figure 3 and remove the magazine Put on the ferrule reel so that it rotates in clockwise direction While inserting the ferrules the transporting pusher...

Страница 9: ...aded again Put in the magazine until it snaps in and close the flap Take care that you have selected the correct cross section program 7 5 Adjustment of the cross section program E confirm select the...

Страница 10: ...n 7 8 0 34 Tooling Set optional Contents Magazine 0 34 Feeding funnel 0 34 Label Figure 6 0 34 Tooling Set optional The H 0 34 12 ferrules may be handled only with the 0 34 tooling set Set the cross s...

Страница 11: ...Adjust the stripping depth of the current program 1 0 34 mm D 0 70mm 2 3 4 5 0 50 mm D 0 90mm 0 75 mm D 0 97mm 1 00 mm D 1 36mm 1 50 mm D 1 69mm 6 2 50 mm D 2 01mm 7 S1 mm Special program 8 S2 mm Spe...

Страница 12: ...p view of a correct stripping The cut edge of the stripping blades have to look like a rue and must be symmetrical to the stranded wires Program Cross section Diameter Wire type Wire manufacturer 1 0...

Страница 13: ...tor 8 Remove the two fixing screws of the key attachment 10 and take it out to the front with the key Turn the stripping slide 7 to the left Take care that the pin at the bottom side of the stripping...

Страница 14: ...ng blades changing position See Figure 8 Striping blades changing position Remove the left red marked screw 5 and the protection plate 4 Unscrew both fixing screws of the table guidance 9 from the bac...

Страница 15: ...it E Exit and back to the operating menu Insert in the magazine Not able to put in a cable Holding clamps are not in starting position Remove the magazine 3x M Motor E 5s Confirm manual operation C S...

Страница 16: ...ard is damaged Keyboard check Main switch and C 0c 0e C 0f E 0d Back to main menu Ferrule misses on the stripped wire Open the flap and remove the magazine If there is a ferrule in the ferrule holder...

Страница 17: ...ion Insert feeding funnel and fix it E Exit and back to the operating menu Insert the magazine Start 0 Wrong triggering The starting switch S1 is activate short Remove magazine Press E The machine goe...

Страница 18: ...Stripping and crimping machine Crimpfix 2 5 M 08 09 19 DK Operating Manual_gb doc 2008 09 19 18 12 Electric diagram...

Страница 19: ...ine Crimpfix 2 5 M 08 09 19 DK Operating Manual_gb doc 2008 09 19 19 13 Spare parts Designation Nr o Stripping blades set CFX 2 5M 9205800000 Transport Holder catch CFX 2 5M 9205810000 Ferrule cutting...

Страница 20: ...ery Directive 98 37 EC EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC Mechanical safety EN ISO 12100 1 EN ISO 12100 2 Electrical safety EN 60 204 1 Emission EN 61000 6 4 2007 Immunity EN 610...

Отзывы: