The valves are devices whose purpose is to ensure the
safety and proper operation of the machine.
Pressure limitation safety valve
The pressure relief valve guarantees that the pressure
Expansion valve- non-return
valve
This is a valve consisting of an expansion
is that of preventing the back flow
of water from the exchangers in
the hydraulic circuit.
The electronic control unit is the nerve centre of
the machine. It monitors and controls all
operation of the unit.
The information related to the installed
The information concerning the
installed software (date and version) can
be seen on the display when the machine is turned on.
The thermostat allows you to avoid damage to the
electrical resistance in case of lack of water in the boiler.
The thermostat bulb
placed at the center of resistance. The contacts of the
thermostat (
) are connected to the electrical resistance
). If the electrical resistance is exposed due to failure
To reset the thermostat, press the center button
. However, before trying to operate the
machine, verify the causes of the blockade of the
water feeding the boiler.