518
Import Active Energy T2-Phase2 (Tariff 2)
32 bit integer
R / W
If password protection is active, enter the
password in the “Settings Protection” field
and then enter “2222” in the “Enable Counter
Change” field. You can then enter the value.
520
Export Active Energy T2-Phase2 (Tariff 2)
32 bit integer
R / W
522
Import Reactive Energy T2-Phase2 (Tariff 2)
32 bit integer
R / W
524
Export Reactive Energy T2-Phase2 (Tariff 2)
32 bit integer
R / W
Tariff 2 Phase 3 Energy Values
526
Import Active Energy T2-Phase3 (Tariff 2)
32 bit integer
R / W
If password protection is active, enter the
password in the “Settings Protection” field
and then enter “2222” in the “Enable Counter
Change” field. You can then enter the value.
528
Export Active Energy T2-Phase3 (Tariff 2)
32 bit integer
R / W
530
Import Reactive Energy T2-Phase3 (Tariff 2)
32 bit integer
R / W
532
Export Reactive Energy T2-Phase3 (Tariff 2)
32 bit integer
R / W
Device Settings
534
Current Transfer Rate (CTR)
32 bit integer
R / W
Enter the password in the “Settings
Protection” field if password protection is
enabled.
536
Voltage Transfer Rate (VTR)
float
R / W
538
Connection Type
32 bit integer
R / W
540
Relay 1 Function (MMW03-M22CH)
32 bit integer
R / W
542
Relay 2 Function (MMW03-M22CH)
32 bit integer
R / W
544
Demand Time
32 bit integer
R / W
546
Password Enable
32 bit integer
R / W
548
Password Activation Time
32 bit integer
R / W
550
Password Value
32 bit integer
R / W
552
Baud Rate
32 bit integer
R / W
554
Slave ID
32 bit integer
R / W
556
Parity Control
32 bit integer
R / W
558
Digital Input 1 Type
32 bit integer
R / W
560
Digital Input 1 Delay Time
32 bit integer
R / W
562
Digital Input 1 Edge
32 bit integer
R / W
564
Digital Input 2 Type
32 bit integer
R / W
566
Digital Input 2 Delay Time
32 bit integer
R / W
568
Digital Input 2 Edge
32 bit integer
R / W
570
Pulse Output 1 Parameter
32 bit integer
R / W
572
Pulse Output 1 Duration
32 bit integer
R / W
574
Pulse Output 1 Rate
32 bit integer
R / W
576
Pulse Output 2 Parameter
32 bit integer
R / W
578
Pulse Output 2 Duration
32 bit integer
R / W
580
Pulse Output 2 Rate
32 bit integer
R / W
582
Menu Scroll On/Off
32 bit integer
R / W
584
Menu Display Period
32 bit integer
R / W
586
Home page Setup
32 bit integer
R / W
588
Display backlight options
32 bit integer
R / W
590
Display backlight on time
32 bit integer
R / W
Alarm Settings
592
Voltage (L-N) Alarm High Limit
float
R / W
Enter the password in the “Settings
Protection” field if password protection is
enabled.
594
Voltage (L-N) Alarm Low Limit
float
R / W
596
Voltage (L-N) Alarm Hysteresis
float
R / W
598
Voltage (L-N) Alarm Delay Time
32 bit integer
R / W
600
Voltage (L-L) Alarm High Limit
float
R / W
602
Voltage (L-L) Alarm Low Limit
float
R / W
604
Voltage (L-L) Alarm Hysteresis
float
R / W
606
Voltage (L-L) Alarm Delay Time
32 bit integer
R / W
608
Current Alarm High Limit
float
R / W
610
Current Alarm Low Limit
float
R / W
612
Current Alarm Hysteresis
float
R / W
614
Current Alarm Delay Time
32 bit integer
R / W
616
Neutral Current Alarm High Limit
float
R / W
618
Neutral Current Alarm Low Limit
float
R / W
620
Neutral Current Alarm Hysteresis
float
R / W
Содержание MMW03-M22CH
Страница 1: ...Motors Automation Energy Transmission Distribution Coatings User Manual Energy Analyzer MMW03 M22CH...
Страница 2: ......
Страница 3: ...User Manual Series MMW03 M22CH Language English Document 10006614878 00...
Страница 4: ......
Страница 41: ...www weg net NOTES Energy Analyzer MMW03 M22CH 41...
Страница 42: ...www weg net NOTES 42 Energy Analyzer MMW03 M22CH...
Страница 43: ...www weg net NOTES Energy Analyzer MMW03 M22CH 43...