60
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Range
[Factory Setting]
Parameter
Description / Notes
Figure 6.6 - V/F curve and details of the manual torque boost
(IxR compensation)
P137
0.00 to 100%
Automatic Torque
[ 0.00 ]
Boost
-
(Automatic IxR
Compensation)
The automatic torque boost compensates for the voltage
drop in the stator resistance as a function of the active
motor current.
The criteria for setting P137 are the same as for the
parameter P136.
Setting P137=100% corresponds to the maximum
increment of the output voltage (30% of P142).
(1)
This parameter can be changed only with disabled inverter (stopped motor).
Output Voltage
(% of the line voltage)
P142
P136
0
P145
Output
frequency
(b) P202=1
Output Voltage
(% of the line voltage)
P142
0,3xP136xP142
0
P145
Output
frequency
(a) P202=0