58
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Multispeed is used when the selection of up to 8 pre-
programmed speeds are required.
It allows the control of the output speed related to the
values programmed by the parameters P124 to P131,
according to the logical combination of the digital inputs
programmed to multispeed.
Activation of the multispeed function:
-
to ensure that the reference source is given by the
multispeed function, i.e., setting P221=6 for local
mode or P222=6 for remote mode;
-
to program one or more digital inputs to multispeed,
according to table below:
The frequency reference is defined by the status of the
digital inputs programmed to multispeed as shown in
table below:
The multispeed function has some advantages for the
stabibilty of the fixed preprogrammed references and the
immunity against electrical noises (digital references and
insulated digital inputs).
Range
[Factory Setting]
Parameter
Description/Notes
P124
(1)
P133 to P134
Multispeed Ref. 1
[ 3.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P125
(1)
P133 to P134
Multispeed Ref. 2
[ 10.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P126
(1)
P133 to P134
Multispeed Ref. 3
[ 20.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P127
(1)
P133 to P134
Multispeed Ref. 4
[ 30.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P128
(1)
P133 to P134
Multispeed Ref. 5
[ 40.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P129
(1)
P133 to P134
Multispeed Ref. 6
[ 50.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P130
(1)
P133 to P134
Multispeed Ref. 7
[ 60.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
P131
(1)
P133 to P134
Multispeed Ref. 8
[ 66.0Hz ]
0.1Hz (<100Hz);
1Hz (>99.9Hz)
DI enable
Programming
DI1 or DI2
P263 = 7/8 or P264 = 7/8
DI3
P265 = 7/8
DI4
P266 = 7/8
DI1 or DI2
DI3
DI4
Freq. Reference
Open
Open
Open
P124
Open
Open
0V
P125
Open
0V
Open
P126
Open
0V
0V
P127
0V
Open
Open
P128
0V
Open
0V
P129
0V
0V
Open
P130
0V
0V
0V
P131
8 speeds
4 speeds
2 speeds
(1)
This parameter can be changed only with disabled inverter (stopped motor).