14 | Worm Gearbox line
24
0,16 - 0,18 0,02 - 0,04
0,02 - 0,04 0,14 - 0,16 0,03 - 0,04
0 - 0,02
0 - 0,02
28
0,18 - 0,20 0,02 - 0,04
0,02 - 0,04 0,16 - 0,18 0,04 - 0,05
0 - 0,02
0 - 0,02
34
0,20 - 0,22 0,02 - 0,04 0,02 - 0,04 0,18 - 0,20 0,04 - 0,05
0 - 0,02
0 - 0,02
6 Lubrication
Proper lubrication is responsible for the performance and service life of the gearbox/geared motor. The
gearboxes are lubricated by oil bath and equipped with a level indicator plug, which can be a level gauge or
a hexagonal plug model HN10-WD (similar to DIN 510), differing from the other plugs in the gearbox/geared
motor.
The correct oil level is in the center of the sight glass (when of the "level glass" type) or in the plug level (when
of the hexagonal plug type) with the gearbox stationary and in the required working position.
Before starting operation, check that the gearbox is filled with oil and that the lubricant level is adequate as
recommended.
The operating temperature is the temperature of the lubricating oil after the temperature stabilization period
at full load (period after approx. 3 hours of continuous operation).
The minimum ambient temperature for the start of operation of gearboxes and geared motors depends on the
viscosity and type of lubricating oil.
The table below shows the minimum ambient temperature for the start-up of gearboxes and geared motors:
Oil
MINIMUM TEMPERATURE
Type
Viscosity
Lubrication
Lubrication
Mineral CLP
ISO VG 220
+2°C
+8°C
ISO VG 320
+7°C
+14°C
Synthetic CLP
HC (PAO)
ISO VG 220
-5°C
+2°C
ISO VG 320
0°C
+8°C
ISO VG 460
+6°C
--- ---
Contact WEG-CESTARI for other temperatures.
The external temperature of the housing is approximately 15°C lower than the operating temperature (oil
temperature).
When changing gears, the oil must be drained while still "warm" because the viscosity of the oil is lower,
facilitating the draining and cleaning.
NOTE:
The lubricant used must be disposed of in accordance with current legislation and the guidelines
contained in the Environmental Guidelines chapter of this manual.
When changing gears, use the same oil as indicated on the gearbox nameplate and specified in this manual.
It is not recommended to mix oils of different types and manufacturers.
The oil must be changed every 3500 hours or annually.
Содержание CESTARI Worm Gearbox line
Страница 1: ...WWW WEGCESTARI COM Worm Gearbox line Instruction Manual ...
Страница 21: ...Worm Gearbox line 8 2 Gearbox faults ...
Страница 23: ...Worm Gearbox line 9 1 Compact Single Inlet assembly ...
Страница 24: ...24 Worm Gearbox line 9 2 Compact single input list ...
Страница 25: ...Worm Gearbox line 9 3 Compact Dual Input Assembly ...
Страница 26: ...26 Worm Gearbox line 9 4 Compact Dual Input List ...
Страница 27: ...Worm Gearbox line 9 5 Assembly Single input ...
Страница 28: ...28 Worm Gearbox line 9 6 Simple Input List ...
Страница 29: ...Worm Gearbox line 9 7 Dual Input Assembly ...
Страница 30: ...30 Worm Gearbox line 9 8 Dual input list ...
Страница 31: ...Worm Gearbox line 9 9 Adaptations Accessories ...
Страница 32: ...32 Worm Gearbox line 9 10 List Adaptations Accessories ...
Страница 33: ...Worm Gearbox line 9 11 Compact input assembly ...
Страница 34: ...34 Worm Gearbox line 9 12 Compact Input List ...
Страница 35: ...Worm Gearbox line 9 13 Adaptations Alumag accessories ...
Страница 36: ...36 Worm Gearbox line 9 14 List Adaptations Alumag Accessories ...