ULTRASOUND
Before treatment
Notes
1.
Cleanse/tone the treatment area using the
prescribed skin-type products.
2.
Remove any left-over product by facial steam for 10
minutes.
3.
Cleanse the treatment area again to remove any dirt
or debris from the face in order to prevent the
ultrasound waves from pushing it back into the dermis.
4.
Tone every part of the face (or treatment area)
gently using a suitable astringent.
5.
After wiping off the astringent, the skin will be
thoroughly cleansed for optimum protection.
6.
Apply enough conductive gel to the treatment area.
Starting treatment
1.
Select the desired ultrasonic probe by pressing
“SELECT”, wave type by pressing “STATE”, the desired
output energy by pressing “ENERGY” and time of
working by pressing “TIMER”. You can change setting
anytime during working.
2.
Press “START/PAUSE” button to start.
•
Always make sure enough conductive gel is applied
for at least 15 minutes of treatment time.
•
Generally, lower outputs are used for facials and
higher outputs for body treatments.
•
If the treatment area is small or sensitive, use the
eye probe and make sure that the energy output is
limited to 5-7 blocks (on the “ENERGY” LCD screen
display). The treatment time may also be reduced to
8-10 minutes.
•
A standard treatment course lasts around 10
sessions in total, with a minimum resting period of 1
day between sessions. If other facial treatments are
being conducted on the same area, a minimum rest
period of 7 days should be observed between
treatments.
Cautions
•
Never use on dry skin.
•
Do not use on the stomach area of pregnant women.
•
Do not use on people with pace-makers (any
electrical or rhythmic heart-regulating device).
•
Do not use on people with known heart conditions.
•
Always use ultrasonic electrodes with enough
moisturizer or serum on the skin.
•
Ultrasonic treatment is suitable for all skin types.
The massage time and machine settings can be
adjusted for each different skin type. For sensitive
skins, reduce treatment time to 3-5 minutes and make
sure the power setting is at the lowest level to start
with.