Cod.006.0001.1040
10/07/2017 v2.12
ENGLISH
WF-103
20/32
11.1.2
MIG/MAG PARAMETERS SETTING (2ND LEVEL)
S1
Hold down the button for 3 seconds to gain access to the 2nd level menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Use the encoder to scroll the list of settings to edit.
E2
Using the encoder, edit the value of the selected setting.
Press any button to save the setting and quit the menu.
Tab. 6 - 2nd level menu parameters in MIG/MAG mode
ACRONYM
PARAMETER
MIN DEFAULT
MAX
H.-S.
HOT START
0 %
130 %
200 %
C.-F.
CRATER FILLER
0 %
80 %
200 %
S.3L.
3 LEVELS SLOPE 0.1 s
0.5 s
10.0 s
S.-S.
SOFT START
10 %
30 %
100 % *1
SLO.
MOTOR SLOPE
0 ms
50 ms
200 ms *1
b.-b.
BOURN BACK
0 ms
25 ms
100 ms *1
11.1.3
MIG/MAG PARAMETERS SETTING (GAS MENU)
S3
Hold down the button for 3 seconds to gain access to the 2nd level menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Use the encoder to scroll the list of settings to edit.
E2
Using the encoder, edit the value of the selected setting.
Press any button to save the setting and quit the menu.
Tab. 7 - Gas menu parameters in MIG/MAG mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
Po.G.
POST GAS TIME 0.0 s
0.3 s
10.0 s *1
Pr.G.
PRE GAS TIME 0.0 s
0 s
10.0 s *1
*1: When a synergic program is loaded the default value of the parameter is defined automatically by the software and the message "SYN" will
be shown on the display.
11.2
ELECTRODE WELDING (MMA)
S6
This button serves to select the following welding mode:
MMA
E1
Using the encoder, edit the value of the following setting: WELDING CURRENT
Tab. 8 - Main welding parameters in MIMA mode
PARAMETER
MIN DEFAULT MAX
WELDING CURRENT
5A
80A
400A *2
5A
80A
500A *3
11.3
ARC AIR (DESEAMING)
S6
This button serves to select the following welding mode:
ARC AIR
E1
Using the encoder, edit the value of the following setting: DESEAMING CURRENT
Tab. 9 - Main welding parameters in ARC AIR mode
PARAMETER
MIN DEFAULT MAX
WELDING CURRENT
5A
80A
400A *2
5A
80A
500A *3
*2: In the 400 Ampere version.
*3: In the 500 Ampere version.
Содержание WF-103
Страница 2: ...Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH WF 103 2 32...
Страница 7: ...WF 103 Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH 0...
Страница 24: ...Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH WF 103 24 32 15 SPARE PARTS 15 1 WF 103...
Страница 28: ...Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH WF 103 28 32 16 ELECTRICAL DIAGRAM 16 1 WF 103...
Страница 29: ...WF 103 Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH 0 29 32 16 2 POWER SOURCE WF 103 CABLE...
Страница 32: ...Cod 006 0001 1040 10 07 2017 v2 12 ENGLISH WF 103 32 32...