4

 

TECHNICAL DATA 

Directives applied 

Waste electrical and electronic equipment (WEEE) 
Electromagnetic compatibility (EMC) 
Low voltage (LVD) 
Restriction of the use of certain hazardous substances  (RoHS) 

Construction standards 

EN 60974-1; EN 60974-10 Class A 

Conformity markings 

  Equipment compliant with European directives in force 

  Equipment suitable in an environment with increased hazard of electric shock 

 

Equipment compliant with directive WEEE 

 

Equipment compliant with directive RoHS 

Supply voltage 

3 x 400 Va.c. ± 15 % / 50-60 Hz 

Mains protection 

10 A Delayed 

Z

max

 

This equipment complies with IEC 61000-3-12 provided that the maximum permissible system 

impedance is less than or equal to 238 mΩ at the interface point between the user's supply 

and the public system. It is the responsibility of the installer or user of the equipment to 

ensure, by consultation with the distribution network operator if necessary, that the equipment 

is connected only to a supply with maximum permissible system impedance less than or equal 

to 238 mΩ. 

Dimensions ( L x D x H ) 

400 x 160 x 260 mm 

Weight 

10 kg 

Insulation class 

Protection rating 

IP23S 

Cooling 

AF: Air-over cooling (fan assisted) 

Static characteristic 

MMA 

 

Drooping characteristic 

TIG 

 

Drooping characteristic 

Current and voltage adjustment range 

MMA 

5 A / 20.2 V - 200 A - 28.0 V 

TIG 

5 A / 10.2 V - 200 A - 18.0 V 

Welding current / Working voltage 

MMA 

40 % (40° C) 

200 A - 28.0 V 

60 % (40° C) 

170 A - 26.8 V 

100 % (40° C) 

130 A - 25.2 V 

TIG 

40 % (40° C) 

200 A - 18.0 V 

60 % (40° C) 

170 A - 16.8 V 

100 % (40° C) 

130 A - 15.2 V 

Maximum input power 

MMA 

40 % (40° C) 

6.7 kVA 

60 % (40° C) 

5.7 kVA 

100 % (40° C) 

4.1 kVA 

TIG 

40 % (40° C) 

4.4 kVA 

60 % (40° C) 

3.6 kVA 

100 % (40° C) 

2.1 kVA 

Maximum supply current 

MMA 

40 % (40° C) 

9.6 A 

60 % (40° C) 

8.1 A 

100 % (40° C) 

5.8 A 

TIG 

40 % (40° C) 

6.4 A 

60 % (40° C) 

5.2 A 

100 % (40° C) 

3.1 A 

Maximum effective supply current 

MMA 

40 % (40° C) 

6.1 A 

60 % (40° C) 

6.3 A 

100 % (40° C) 

5.8 A 

TIG 

40 % (40° C) 

4.0 A 

60 % (40° C) 

4.0 A 

100 % (40° C) 

3.1 A 

No-load voltage (U

0

MMA 

61 V 

TIG 

61 V 

Reduced no-load voltage (U

r

TIG 

13 V 

 

 

Содержание Discovery 200 S

Страница 1: ...1 1320 22 05 2019 v2 8 ENGLISH WECO srl Via S Antonio 22 BELVEDERE 36050 TEZZE SUL BRENTA VICENZA ITALY Tel 39 0424 561943 Fax 39 0424 561944 www weco it E mail info weco it Discovery 200 S GB Instruc...

Страница 2: ...Cod 006 0001 1320 22 05 2019 v2 8 ENGLISH Discovery 200 S 2 14...

Страница 3: ...ONS TO THE ELECTRICAL MAINS NETWORK 4 2 2 FRONT PANEL 4 2 3 REAR PANEL 5 2 4 PREPARING FOR MMA WELDING 5 2 5 PREPARING FOR TIG WELDING 6 3 COMMISSIONING 7 3 1 USER INTERFACE 7 3 2 WELDING PARAMETERS 8...

Страница 4: ...tdoor applications The available DC TIG functions and digital control make this unit ideal for maintenance building construction and light metalwork In MMA welding the Hot Start and Arc Force function...

Страница 5: ...der cable to the welding socket based on the polarity requested by the type of electrode used 6 Connect the plug of the ground clamp to the welding socket on the basis of the polarity required 7 Conne...

Страница 6: ...of the polarity required 7 Connect the earth clamp to the workpiece being processed 8 Set the welding power source ON OFF switch to I unit powered 9 Select the following welding mode on the user inter...

Страница 7: ...show that the following welding mode is selected MMA L4 This LED illuminates to show that the following welding mode is selected PULSED DC TIG L5 This LED illuminates to show that the following weldi...

Страница 8: ...ding During electrode fusion low conductivity parts of the coating become detached and tend to become interposed between the electrode tip as it is fusing and the workpiece This condition results in a...

Страница 9: ...sultation with the distribution network operator if necessary that the equipment is connected only to a supply with maximum permissible system impedance less than or equal to 238 m Dimensions L x D x...

Страница 10: ...Cod 006 0001 1320 22 05 2019 v2 8 ENGLISH Discovery 200 S 10 14 5 SPARE PARTS...

Страница 11: ...2 0004 KNOB WITH CUP WITHOUT INDICATOR 13 050 0004 0013 FILTER BOARD 14 011 0003 0001 LOWER COVER 15 042 0003 0010 POWER TRANSFORMER 16 015 0001 0005 HEAT SINK 17 032 0002 2003 ISOTOP DIODE 18 050 000...

Страница 12: ...Cod 006 0001 1320 22 05 2019 v2 8 ENGLISH Discovery 200 S 12 14 6 ELECTRICAL DIAGRAM 6 1 DISCOVERY 200 S...

Страница 13: ...Discovery 200 S Cod 006 0001 1320 22 05 2019 v2 8 ENGLISH 13 14 6 2 REMOTE CONTROLLER CONNECTOR Welding side cod 021 0004 0602 Remote Controller 2 kOhm 10 kOhm potentiometer...

Страница 14: ...Cod 006 0001 1320 22 05 2019 v2 8 ENGLISH Discovery 200 S 14 14...

Отзывы: