WELD THE WORLD
Cod. 006.0001.1820
25/05/2018 V.2.6
Cruiser 322/402/502AC/DC
Power Pulse 322/402/502AC/DC
8
ENGLISH
•
Number and cross section of wires: 4 x 6 mm
2
(4 mm
2
on 322AC/DC)
•
Power plug type: not supplied
○ Socket for connecting the power cable between the power source and the remote control device
[Item 9].
○
(Only
Power Pulse 322/402/502AC/DC) Connector for connection to the programmer [Item 10].
Programming connector for the “pulsed” circuit board. You can update the software of the equip
-
ment using the programming kit.
2.4 PREPARING FOR MMA WELDING
1. Set the welding power source ON/OFF switch to “O” (unit switched off).
2. Plug the power cable plug into a mains socket outlet.
3. Choose the electrode based on the type of material and thickness of the workpiece to be welded.
4. Insert the electrode in the electrode holder.
5. Connect the electrode holder cable to the welding socket based on the polarity requested by the
type of electrode used.
6. Connect the plug of the ground clamp to the welding socket on the basis of the polarity required.
7. Connect the earth clamp to the workpiece being processed.
DANGER!
Electric shock hazard!
Read the warnings highlighted by the following symbols in the “General prescriptions for use”.
8. Set the welding power source ON/OFF switch to “I” (unit powered).
9. Select the following welding mode on the user interface: MMA
10. Set the required welding parameter values on the user interface.
When the remote controller [RC] is connected and the relative locking screw is tightened, welding
current can be adjusted using the remote controller.
The system is ready to start welding.
REAR VIEW
FRONT VIEW
(polarity to basic electrode)
RC
Antwerpsesteenweg 949 9041 Gent - Oostakker
[email protected]
www.welda.be
T
+32 (0)9 355 74 26
F
+32 (0)9 355 92 01