WELD THE WORLD
Cod. 006.0001.1820
25/05/2018 V.2.6
Cruiser 322/402/502AC/DC
Power Pulse 322/402/502AC/DC
54
ENGLISH
12 TECHNICAL DATA
Directives applied
Waste electrical and electronic equipment (WEEE)
Electromagnetic compatibility (EMC)
Low voltage (LVD)
Restriction of the use of certain hazardous substances (RoHS)
Construction standards
EN 60974-1; EN 60974-3; EN 60974-10 Class A
Conformity markings
Equipment compliant with European directives in force
Equipment suitable in an environment with increased hazard of electric shock
Equipment compliant with WEEE directive
Equipment compliant with RoHS directive
12.1 CRUISER 322 AC/DC - POWER PULSE 322 AC/DC
Supply voltage
3 x 400 Va.c. ± 15 % / 50-60 Hz
Mains protection
25 A 500 V Delayed
Zmax
This equipment complies with IEC 61000-3-12 provided that the maximum permis
-
sible system impedance is less than or equal to 38 mΩ at the interface point between
the user’s supply and the public system. It is the responsibility of the installer or user
of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with maximum permis
-
sible system impedance less than or equal to 38 mΩ.
Dimensions ( L x D x H )
690 x 290 x 450 mm
Weight
46.4 kg
Insulation class
H
Protection rating
IP23
Cooling
AF: Air-over cooling (fan assisted)
Maximum gas pressure
0,5 MPa (5 bar)
Static characteristic
MMA Falling characteristic
TIG Falling characteristic
MIG/MAG Flat characteristic
Welding mode
MMA
TIG
MIG/MAG
Current and voltage adjustment
range
10 A - 20.4 V
300 A - 32.0 V
5 A - 10.2 V
320 A - 22.8 V
20 A - 15.0 V
320 A - 30.0 V
Welding current / Working voltage
45% (40° C)
300 A - 32.0 V
320 A - 22.8 V
--
40% (40° C)
--
--
320 A - 30.0 V
60% (40° C)
270 A - 30.8 V
280 A - 21.2 V
270 A - 27.5 V
100% (40° C)
240 A - 29.6 V
240 A - 19.6 V
240 A - 26.0 V
Maximum input power
45% (40° C)
14.7 kVA – 11.3 kW
13.1 kVA – 9.9 kW
--
40% (40° C)
--
--
15.2 kVA – 12.0 kW
60% (40° C)
12.7 kVA – 9.8 kW
10.5 kVA – 7.6 kW
12.1 kVA – 9.3 kW
100 % (40° C)
11.2 kVA – 8.6 kW
8.8 kVA – 6.1 kW
10.5 kVA – 7.8 kW
Antwerpsesteenweg 949 9041 Gent - Oostakker
[email protected]
www.welda.be
T
+32 (0)9 355 74 26
F
+32 (0)9 355 92 01