This serves to start the cooler for 15 seconds to fill the torch cooling circuit.
- St.C. [STARTING CURRENT]
○ The value of this parameter can be set as a percentage of the welding current or as an absolute
value expressed in Amperes.
- F.C. [FINAL CURRENT]
○ The value of this parameter can be set as a percentage of the welding current or as an absolute
value expressed in Amperes.
- HF.C. [HF CURRENT]
○ This parameter establishes the current value during HF discharge. The value of this parameter
can be set as an absolute value or in SYN.
○ With SYN setting the HF current value is calculated automatically on the basis of the pre-set weld
-
ing current value.
Consequences of a higher value:
•
Arc striking is facilitated, even on very dirty workpieces.
•
Risk of piercing excessively thin gauge workpieces.
- HF.t. [HF TIME]
○ This parameter defines the maximum high frequency (HF) arc strike duration.
- PUL. [TYPE OF PULSED CURRENT]
○ SLo. = This setting enables slow pulsed mode. The peak time and base time are set.
○ FA.= This setting enables fast pulsed mode. The frequency and duty-cycle are set.
- P.A. [PILOT ARC]
○ The function enables the output of a low current between the 1st and 2nd times of the torch trig
-
ger to shield the mask in advance and avoid the risk of blinding flashback caused by the welding
current.
- C.C.E CONTACT COMMAND EXPANSION
○ The function enables the emission of the ARC-ON and ALARM signals via the signal connectors
for automatic applications.
- E.r.C. [ENABLE READ CURRENT]
○ This function allows for the real welding current display to be enabled or disabled.
- StS [SPECIAL TORCH STROKE]
○
The parameter changes the torch trigger operating mode.
• oFF: indicates standard operation.
•
1: specifies the 4T B-level management variant. Allows the transition to the secondary welding
current by pressing and holding down the UP or DOWN button; when the button is released,
the primary current is restored. With variant oFF selected, the UP/DOWN buttons are disabled
for all procedures.
•
2: specifies the down slope management variant. By releasing the torch trigger during the third
stroke (3S) the down slope is stopped and the final current is immediately delivered without
having to go through the entire slope time.
- F.r.C. [COMMAND TYPE PEDAL]
○ The parameter selects the type of pedal used:
• RC02 standard pedal type