CR
8
19
1
1
1
1
Changing the fuse
Remove the protective cap (1) of the fuse holder.
Insert a new fuse with rated value of 20 Amp.
Changing the oil in the exciter
Remove the oil drain screw (1) and drain oil.
To fill – tilt the machine slightly and fill with fresh oil through
the drain opening in accordance with the fill level table.
Checking the V-belt
Remove the V-belt guard (1).
Check the V-belt (1) for cracks, damaged flanks, and wear.
If there is excessive wear – replace the V-belt as specified
in the repair manual.
Select a collection vessel that is large enough to pre-
vent oil from spilling on the ground. Dispose of waste
oil in an environmentally friendly manner (regulation
on waste oils).
Wipe up / off oil slick and oil residue and dispose of
fuel-soaked cleaning cloths in an environmentally re-
sponsible manner.
The fuses are housed behind the side panel on the
left in the direction of travel.
Содержание CR 8