13
Start using e-start
Bring the gas lever (1) into full-throttle position.
Check the hydraulic oil level when the machine is at
operating temperature. The correct oil level is reached when
the oil is in the middle of the view glass.
Check the hydraulic fluid level
Move vibration lever (2) to position ( ).
Insert the ignition key (1) and turn to position 1.
Turn the ignition key (1) to position 2.
The ignition key must bounce back to pos. 1 and
remain in this position during operation. The charge
level indicator (3) and the oil pressure indicator (4)
must go out immediately after starting.
The indicator lamp (2) lights up, indicating that the
engine is in operation.
Release the ignition key as soon as the engine starts
The operating hours counter (7) will keep counting the
operating hours as long as the ignition is switched on.
If the ignition key does not bounce back to pos. 1 - turn
off the machine immediately - danger of starter da
-
mage due to the starter also running during operation
Start for a maximum of twenty seconds without inter-
ruption. If the engine does not start, repeat starting
process after a minute. If the engine does not start
after two start processes, seek cause in fault table.
1
2
1
3
2
4
5
6
7
Содержание 0140302