9
Lexus GS 450h
1
Red (rt) wire, Ø 6 mm pointed cable socket
2
Positive base
Connec-
ting to the
positive
supply
Run the brown (br) wire for the heater unit
cable harness ground supply
3
through the
cable socket
1
to the grounding point
2
and
connect.
Connec-
ting the
ground
supply
Pull the rt and sw (red and black) lines from
the K3 blower relay and the time switch cable
harness into the remaining Ø20 mm tube
shaft and to the cable feed-though.
Wrap the tube ends with insulation tape.
Note:
Pull the lines from the K3 blower relay and the
time switch cable harness from the interior
through the feed-though.
Installing
lines
11
1
2
12
2
3
1
13
1