Ram ProMaster
Ibiza
10
In addition to a pressure regulating valve and gauges, always install a pressure relief valve. This can also be a frangible
disc type pressure relief device. This device should have a discharge port of at least 1/2” MPT size. The valve or frangible
disc device must be set to release at 175 PSIG.
• Do not pressurize the system beyond 150 PSIG field leak test pressure. When field testing a system for leaks, 150
PSIG is adequate test pressure.
• Disconnect nitrogen cylinder and evacuate the system before connecting the refrigerant container. Disconnect the
nitrogen cylinder and release the pressure in the system before connecting a refrigerant container to the system.
The higher pressure gas in the system can explode the refrigerant container.
1.3 Scope
These non-binding installation instructions are intended to support trained or certified dealers, and personnel in the
installation of the Webasto HVAC units. Provided these instructions are followed properly and all options listed in the
parts breakdown are installed, this system will provide supplemental heating and cooling.
1.4 Applicability of Manual
These non-binding installation instructions apply to the make/model listed on the front cover of this installation manual.
Due to optional equipment, there may be build variations between this installation manual and the vehicle you are work-
ing on. Technical modifications that differ from the instructions set forth exclude all liability claims. Acknowledged engi-
neering conventions must be observed for the installation work. Carefully read all documentation prior to installation.
a
CAUTION
Location of the Webasto provided components, wiring and control devices are important for proper operation. Failure to
comply with the installation instructions provided may result in poor operation or damage to the Webasto unit, the vehi-
cle, or vehicle components.
Non-compliance with the installation instructions and information contained therein will void the warranty. The same
applies for repairs performed by untrained personnel and repairs not using original equipment spare parts.
1.5 Meaning of Warnings, Cautions and Notes
WARNING:
This heading is used to highlight that non-compliance with instructions or procedures may cause injuries or lethal
accidents to personnel.
a
CAUTION:
This heading is used to highlight that non-compliance with instructions or procedures may cause damage to equipment.
NOTE:
This heading is used to highlight and draw specific attention to information.