4.3 

Irritations not  indicated by monitoring switches 

 

1.

 

No chlorine dosing: no free chlorine in pool water 

 
    By using the test program chlorine on facsia no dosing 

-

 

dosing screw blocked 

-

 

dosing screw loose 

-

 

dosing nozzle (heated) faulty or blocked 

-

 

dosing motor faulty 

 
If dosing works by using the test program see to auto-controller for free chlorine whether the 
output is correct 

 

2.

 

No acid dosing: pH in pool water is high, suction tube/mixing chamber is turbid. 

If acid container is not empty, no fault indication at the fascia: check dosing function of acid pump 
use test program for acid. If pump runs, see whether an air bubble is sucked to pump, if not 
examine the pump roller and pump hose. If all is OK, increase dosing rate and choose lower set 
point for pH  

 

3.

 

Continuous dosing of chlorine or acid on program “auto” without command from the 

auto-controller: Check whether the output from the auto-controller is correct – no voltage from 
there. If so, the 130 volt relay of the GRANUDOS input is faulty. Replace the relay or mount a 
new power plate.  

 

4.

 

Overflow from tank too much at switch off of GRANUDOS 

-

 

switch bobbin of flow switch is blocked on top situation or does not fall down completely 

-

 

joint of switch bobbin faulty 

-

 

diaphragm of the floating valve faulty 

-

 

piston of floating valve is blocked by impurities (sand if diaphragm is faulty) 

-

 

supply pressure of an external booster pump too high 

-

 

set in spring-loaded check valve in ell of floating valve. Please make sure that because of 
pressure drop you will need a pressure of at least 0,4 bar 

 
 

 

Содержание GRANUDOS 10-V61

Страница 1: ...id may not be mixed together or with other chemicals Pay attention to the safety devices on chemical Containers 2 Close hopper immediately after filling 3 If an adapter to a chemical container is used...

Страница 2: ...al Connection 9 3 Start up operation 9 3 1 Deaeration of water supply tubing 9 3 2 Water level in flushing tank 9 3 3 Water flow Suction performance of injector 9 3 4 Filling of Chlorine into hopper 9...

Страница 3: ...ystem Measures base 60 x 50 cm height 80 cm weight 30 kg Material PE polyethylene Booster Pump centrifugal pump SS 0 3 kW 230 Volt supply pressure 0 2 1 2 bar counter pressure 0 1 2 bar depending on s...

Страница 4: ...ing hopper The required dosing rate is adjusted at the control board by means of a dosing cycle and dosing time see para 1 5 5a dosing hopper 5b hopper cover 6a dosing motor 6b motor holder 6c dosing...

Страница 5: ...intervals para 3 7 Adjusting dosing performance power supply for chlorine and acid dosing motors are connected by a relay system so that only one or none of them can get power 24VDC and dose chemical...

Страница 6: ...s switched off Chemicals on reserve is only indicated All faults normally activate the fault remote control The control system is enclosed within a dust proof and splash proof housing IP 65 External s...

Страница 7: ...d pH If control time exceeds 50 there must be an interruption in the system too high bathing load interruption at the dosing appliance blocked screw broken hose faulty motor etc interruption at the au...

Страница 8: ...sible At works the GRANUDOS has been tested at following pressure conditions Service pressure 1 2 bars Counter pressure 1 2 bars 0 6 bars 0 8 bars 0 3 bars 0 5 bars Within these ranges the GRANUDOS sh...

Страница 9: ...f he get s empty switch off the pump machine and wait till the filter is full again then switch on again On operation the filter must be and stay full of water a little air at top staying steadily doe...

Страница 10: ...t side of the housing is delivered with loose dosing hose to prevent deformation on stock time Push the hose back into the yellow housing and turn the roller clockwise some times so that the hose is s...

Страница 11: ...rolled by Auto Controller If an auto controller is used set an E Programme see above and use app 3 5 times higher dosing rate as calculated above It is to adjust both cycle and dosing time If CO2 is u...

Страница 12: ...439 6 0 5 3 0 5 6 2 411 8 1 6 1 13 3 342 9 1 5 9 1 5 19 4 285 11 2 13 2 25 5 238 13 2 5 16 2 5 31 6 198 16 3 19 3 38 7 165 19 3 5 22 3 5 44 8 138 23 4 25 4 50 9 115 28 5 31 4 5 56 10 95 34 6 38 5 63 1...

Страница 13: ...front fascia switch Glimmering indicates filling of buffer tank with programme PB Red LED shows function of dosing and interruptions indicated by the different Sensors At any interruption dosing stop...

Страница 14: ...m of tube By pressing the connecting hose to the suction tube the bobbin does not move switch LED burns Possibilities at installation service pressure too low counter pressure too high tubing faulty o...

Страница 15: ...e whether an air bubble is sucked to pump if not examine the pump roller and pump hose If all is OK increase dosing rate and choose lower set point for pH 3 Continuous dosing of chlorine or acid on pr...

Страница 16: ...if so contact your supplier check monthly for the acid pump whether the springs are o k If corrosion can be seen change the dosing hose In any case change it once per year monthly or with each new dr...

Страница 17: ...315 m amp slow Transformers Tr1 transformer for power outputs 18 volt 16 va Tr2 transformer for control system 6 volt 1 5 va Relays SSR 1 solenoid knocker 240 v solid state relay Rel 2 booster pump 24...

Страница 18: ...lled outputs 24 VDC switch of dissolving unit normal open 1 2 heater dosing nozzle 1 level W max blue 3 chlorine dos 24 VDC 2 level W min brown 4 chlorine dos 24 VDC 3 mass level switches black 5 acid...

Страница 19: ...MCU 1c 11505 Power plate NRGRD 6 11517 Power transformer 240 18 volt 16VA 11665 Control transformer 240 6V 2VA 10929 main switch 11338 fuse holder GR 12324 Knob 4mm 11757 Cover control box GR10 10796...

Страница 20: ...tank flow switch holder change connecting hose if brittle 1 8 check pump end plate at Calpeda pump only change pump end plate 1 9 check tightness of pump OK new slide ring seal 1 10 check ball bearing...

Отзывы: