background image

  

VIP Series

Submersible Utility Pumps

OPERATING INSTRUCTIONS 

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, serious injury or death.

For parts, product & service information visit

 www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2016,  
WAYNE/Scott Fetzer Company.

1

DESCRIPTION

This portable, submersible utility pump is designed and in tend ed for 
non-automatic use in water.  The units are equipped with an 8-ft. 3-prong 
ground ing-type power cord. The motor is oil filled and sealed for cooler 
running and designed to operate under water. The non-clogging impeller 
design minimizes debris from stopping the pump. The elbow fitting allows 
convenient discharge through a garden hose.

IMPORTANT: THIS PUMP IS NOT SUITABLE FOR AQUATIC LIFE!

UNPACKING

After unpacking the sumbersible utility pump, carefully inspect for any 
damage that may have occurred during transit. Check for loose, missing 
or damaged parts.

SAFETY GUIDELINES

To help recognize this information, observe the following signal words/
hazard classifications.

 

DANGER indicates an imminently hazardous 

  situation which, if NOT avoided, WILL result in 

death or serious injury.

 

WARNING indicates a potentially hazardous 

  situation which, if NOT avoided, COULD result in 

death or serious injury.

 

CAUTION indicates a potentially hazardous 

  situation which, if NOT avoided, MAY result in 

minor or moderate injury.

 

NOTICE indicates important information, that if 

  NOT followed, MAY cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential 

bodily injury hazards. Obey all safety messages that follow this 

symbol to avoid possible harm.

NOTE: Information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

 

This product contains chemicals known to the  

  state of California to cause cancer or birth 

defects or other reproductive harm. California’s Proposition 65 requires 

this warning to be given to customers in the state of California.

GENERAL SAFETY

1.  Read manual included with this product carefully. Be 

thoroughly familiar with the controls and the proper use 
of the equipment. 

2.   Know the pump application, limitations, and potential 

hazards. Read these rules and the instructions carefully. Failure 
to follow them could cause serious bodily injury and/or property 
damage.

 Do 

NOT use to pump flammable or 

  explosive fluids such as gasoline, 

fuel oil, kerosene, etc. Do not use in a flammable and/or 

explosive atmosphere. Pump SHOULD be used to pump clear 

water ONLY. Personal injury and/or property damage COULD 

result.

3.  Make certain that the power source con forms to the requirements of 

the equipment.

 

Disconnect  power  be fore  ser vic ing.   

  If the power dis con nect is out of 

sight, lock in the open (OFF) po si tion and tag it to prevent 

un ex pect ed  ap pli ca tion  of  pow er.  Fail ure  to  do  so  COULD 

result in fa tal elec tri cal shock!

4.  Release all pressure within the system before ser vic ing any 

component.

5.  Drain all liquids from the system before servicing.
6.  Secure the discharge line before starting the pump. An unsecured 

discharge line will whip, possibly caus ing personal injury and/or 
property damage.

7.  Check hoses for weak and worn condition before each use, making 

certain that all connections are secure.

8.  Periodically inspect the pump and system com po nents. Perform 

routine maintenance as required (See Main te nance Section, on page 
3).

 

This utility pump is not constructed to handle 

  laun dry discharge or any other application 

which may contain caustic chemicals and/or foreign ma te ri als. This 

pump is NOT a pond or waterfall pump – use of the pump in these 

applications will void the warranty. Pump damage COULD occur if the 

pump is used in these ap pli ca tions.

9.  Provide a means of pressure relief for pumps whose discharge line 

can be shut-off or obstructed.

10.  Personal Safety:

a.  Wear safety glasses at all times when working with pumps.
b.  Keep work area clean, uncluttered and prop er ly light ed; replace all 

unused tools and equipment.

c.  Keep visitors at a safe distance from the work area.

11.  When using an electrically driven pump such as this, follow all 

electrical and safety codes, as well as the most recent National 
Electrical Code (NEC) and the Oc cu pa tion al Safety and Health Act 
(OSHA).

12.  This equipment is only for use on 120 volt (single-phase) and 

is equipped with an ap proved 3-conduc tor cord and 3-prong, 
grounding-type plug as shown in Figure 1.

 

To reduce the risk of electric shock, the motor must be securely and 
adequately grounded. This can be ac com plished by inserting pump 

3200 

06

 -001 4/16

Содержание VIP Series

Страница 1: ...uipment 2 Know the pump application limitations and potential hazards Read these rules and the instructions carefully Failure to follow them could cause serious bodily injury and or property damage Do...

Страница 2: ...direction Thread garden hose onto the elbow fitting NOTE The garden hose must be 3 4 in or larger to keep friction as low as possible A 1 1 4 in sump discharge hose adapter can be connected directly...

Страница 3: ...LESHOOTING CHART Symptom Possible Cause s Corrective Action Pump will not start or run 1 Blown fuse or tripped circuit breaker 1 If blown replace with proper sized fuse or re set break er 2 Low line v...

Страница 4: ...ns might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of c...

Страница 5: ...la aplicaci n limitaciones y posibles riesgos de la bomba Lea estas reglas e instrucciones cuidadosamente El no seguirlas podr a causar graves lesiones corporales y o da os a la propiedad No BOMBEE l...

Страница 6: ...ire el adaptador acodado hasta que el anillo en O quede sellado contra el cuerpo de la bomba y la descarga se encuentre en la direcci n deseada Enrosque la manguera de jard n en la conexi n acodada NO...

Страница 7: ...l ctrico de motor para su lubricaci n y la transferencia de calor del motor Este aceite PUEDE ser da ino para el medio ambiente Verifique las leyes ambientales del estado antes de eliminar este aceite...

Страница 8: ...un estado a otro Bajo ninguna circunstancia aunque sea debido al incumplimiento del contrato de garant a culpabilidad in cluyendo negligencia u otras causas la compa a Wayne o ninguno de sus surtidor...

Отзывы: