Troubleshooting Chart

 

ELECTRICAL PRECAUTIONS - Before servicing a pump, always shut off the main power breaker and then unplug 

  the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes. Under fl ooded 

conditions, contact your local electric company or qualifi ed licensed electrician for disconnecting electrical service prior to pump removal.

Symptom

Possible Cause(s)

Corrective Action

 Pump will not run

 1. Power 

off

2.  Blown fuse or tripped breaker

3.  Faulty pressure switch

4.  Motor overload tripped

 1.  Turn power on or call power com pa ny

2.  Replace fuse or reset circuit break er

3. Replace switch

4.  Let cool. Overload will au to mat i cal ly re set

Motor hums but will not run

1.  Voltage does not match selector switch

2.  Wiring too small

3.  Damage or misalignment causing rotating 

parts to bind

1. Check voltage

2.  Rewire. See Chart 4*

3.  Replace or take to service shop for re pair

Overload trips

1.  Incorrect line voltage 

2.  Damage or misalignment causing rotating 

parts to bind

3.  High surrounding temperature

4. Rapid 

cycling

1.  Rewire. See Chart 4*

2.  Take to motor repair shop or locate and repair 

mechanical binding

3.  Provide a shaded, well-ventilated area for pump

4.  Pump starts and stops too often sec tion

Pump runs but delivers little or 
no water

1.  Water level below pump intake

2.  Control valve open too far (deep well)

3.  Discharge not vented while priming

4.  Leaking in piping on well side of pump

5.  Well screen or inlet strainer clogged

6.  Clogged nozzle (deep well)

7.  Air volume control diaphragm ruptured

8.  Foot valve may be clogged or stuck closed

9.  Pump not fully primed

10. Control valve completely closed (deep well)

11. Water level below maximum lift spec i fi ca tion

12. Undersized piping

13. Gaseous well

14. Distorted venturi

15. Incorrect jet for application

16. Undersized pump

17. Pump cavitates, sounds like pumping gravel

1.  Lower suction pipe further into well

2.  Adjust control valve or repeat priming procedure.

3.  Open faucet, repeat priming pro ce dure

4.  Repair piping as needed

5.  Clean or replace as necessary

6.  Pull jet and clear obstruction

7.  Repair or replace air volume control

8.  Clean or replace as needed

9.  Continue priming, paus ing ev ery 5 min utes to cool 

pump body. Refill pump as need ed

10. Adjust control valve per deep well prim ing 

procedure

11. Select applicable pump and/or jet as sem bly

12. Replace as needed

13. Install baffle on pump intake to pre vent gas from 

entering system

14. Inspect and replace

15. Purchase a jet matched to your sys tem when 

replacing another brand pump

16. Increase horsepower of pump

17. Increase suction plumbing diameter or decrease 

pipe friction

Pump starts and stops too of ten

1.  Water logged tank (conventional tank)

2.  Air volume control tubing kinked or clogged

3.  Air volume control tubing connected to 

wrong opening on pump

4.  Incorrect tank pre-charged (pre-charged 

tank)

5.  Ruptured diaphragm/bladder (pre-charged 

tank)

6.  Leak in house piping

7.  Foot valve or check valve stuck open

8.  Motor overload tripping

9.  Improperly adjusted pressure switch 

1.  Replace tank or air volume control

2.  Clean or replace as needed

3.  Move to correct pump opening

4.  Add or release air as needed

5. Replace tank

6.  Locate and repair leak

7.  Remove and replace

8.  See overload trips section

9.  Readjust or replace switch

Содержание Shallow well model

Страница 1: ...ure 6 Periodically inspect pump and system components Perform routine maintenance as required See Maintenance 7 Personal Safety a Wear safety glasses at all times when working with pumps b Keep work a...

Страница 2: ...r This barrier prevents the air from being absorbed into the water and allows the water to be acted on by compressed air at initially higher than atmospheric pressures precharged More usable water is...

Страница 3: ...oints or couplings will allow air to leak into the pipe and cause abnormal pump operation Make sure to use pipe joint compound on all male pipe threads DUG WELL CISTERN LAKE AND SPRING INSTALLATION FI...

Страница 4: ...ny maintenance Operation PRIMING THE SHALLOW WELL PUMP To prevent damage to the pump do not start motor until pump has been filled with water 1 Remove prime plug Figure 4 or 5 2 Fill pump and piping c...

Страница 5: ...from impeller hub and seal plate INSTALLING NEW SHAFT SEAL Before handling shaft seal parts wipe hands clean Dirt or grease can damage the seal 1 Wet the inside of the seal cavity on seal plate and th...

Страница 6: ...6 Operating Instructions and Parts Manual Shallow Well Model Systems www waynepumps com Notes...

Страница 7: ...7 Operating Instructions and Parts Manual Shallow Well Model Systems Notes www waynepumps com...

Страница 8: ...8 Operating Instructions and Parts Manual Shallow Well Model Systems www waynepumps com Notes...

Страница 9: ...well 7 Air volume control diaphragm ruptured 8 Foot valve may be clogged or stuck closed 9 Pump not fully primed 10 Control valve completely closed deep well 11 Water level below maximum lift specific...

Страница 10: ...assembly 56393 56393 56393 1 6 Impeller 23285 021 23285 022 23285 022 1 7 Diffuser 17148 021 17148 021 17148 021 1 8 Screw 67007 001 67007 001 67007 001 2 9 O ring 15557 15557 15557 1 10 Venturi 1715...

Страница 11: ...concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILL...

Страница 12: ...AGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages...

Страница 13: ...d essayer de monter de d placer ou de proc der au service ou l entretien Verouiller le sectionneur de puissance dans la position ouverte tiquetter le sectionneur de puissance afin d viter l alimentat...

Страница 14: ...de d charge basse tension tr s lev e ou basse installation de fils incorrecte branchements de moteur incorrects ou moteur pompe d fectueux Pr Installation SOURCES D EAU Les sources d eau possibles so...

Страница 15: ...mpe pour puits de surface si la pompe est situ e moins de 7 62 m verticalement du niveau d eau Les pompes pour puits de surface ont un seul tuyau entre la pompe et la source d eau Figure 3 PUITS FOR F...

Страница 16: ...La tension de la source d alimentation doit correspondre avec la tension de la pompe Toutes les pompes de puits de surface sauf le mod le SWS50BOOST ont des moteurs tension double pr r gl s en usine 1...

Страница 17: ...le plus bas du syst me pour dissiper toute l eau pressuris e dans le syst me 3 Amorcer la pompe Amor age De Pompes Pour Puits De Surface 4 Brancher nouveau l alimentation la pompe REMARQUE Lors du rem...

Страница 18: ...assure le vidange et l amor age correct 3 Positionner la pi ce du joint d arbre rotative sur la turbine et appuyer soigneusement afin de ne pas appuyer sur la surface polie du joint 4 Positionner la t...

Страница 19: ...effonde D PUITS ENFONC Un tuyau avec un tamis pointu est enfonc dans la terre sous le niveau hydrostatique La profondeur est g n ralement moins de 15 m Les diam tres disponibles sont 2 5 cm 5 1 cm E P...

Страница 20: ...anneau carr 17150 001 1 5 Assemblage de bo te d tanch it 56393 1 6 Rotor 23285 002 1 7 Diffuseur 17148 001 1 8 Vis 67007 001 9 Joint torique 15557 1 10 Venturi 17151 002 1 11 Buse 15672 1 12 Bouchon...

Страница 21: ...aisser la circulation aller retour de la pompe b Purger l air enferm dans la pompe normalement cause d une vanne ferm e dans la plomberie de d charge 2 Filtre en ligne r duit la circulation 2 V rifier...

Страница 22: ...dur e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e donne l acheteur des...

Страница 23: ...s materiales 5 Antes de cada uso inspeccione las mangueras para cerciorarse de que no est n d biles ni gastadas Aseg rese de que todas las conexiones est n seguras 6 Inspeccione peri dicamente la bomb...

Страница 24: ...cisterna Esta agua habitualmente no es adecuada para consumo humano pero podr a usarse para lavar irrigar u otros usos dom sticos AGUAS SUBTERR NEAS El agua que se encuentra en los diversos estratos p...

Страница 25: ...vula de aspiraci n debe estar por lo menos a 45 cm 18 pulg del fondo del pozo de no ser as podr a aspirar arena o sedimento dentro del sistema 4 Despu s que se haya alcanzado la profundidad adecuada i...

Страница 26: ...i n sobre superficie excepto la SWS50BOOST tienen motores de doble voltaje preconfigurados en la f brica a 115 voltios Para conectarlas a circuitos de 230 voltios simplemente gire la perilla al voltaj...

Страница 27: ...ebe haber agua en la cubierta en espiral de la bomba voluta cuando este funcionando para evitar danos internos en las piezas de sellado Vea las secciones sobre cebado de pozos poco profundos o de pozo...

Страница 28: ...alineadas con las leng etas del armaz n del motor Figura 11 Esta ubicaci n se debe hacer para asegurar un drenaje y cebado adecuados 3 Sit e la pieza rotatoria del sello del eje en el impulsor y pres...

Страница 29: ...el flujo hacia y desde la bomba b Deje salir el aire atrapado en la bomba normalmente debido a una v lvula cerrada en la tuber a de salida 2 El filtro en l nea est restringiendo el flujo 2 Verifique...

Страница 30: ...A No de Ref Descripci n No Repuestos Cte 1 Motor 32059 001 1 2 Tornillo 16636 002 3 Plato de cierre 17145 001 1 4 Junta cuadrada de goma del anillo 17150 001 1 5 Ensamblaje de sellado del eje 56393 1...

Страница 31: ...POZO ACCIONADO Se acciona una tuber a con una pantalla con punta en la tierra por debajo de la capa fre tica La profundidad por lo general es menor a 15 25 m 50 pies Los di metros comunes fluct an ent...

Страница 32: ...XCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites en los da os por incidentes o consecu...

Отзывы: