![Wayne Reliance G6101D Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/wayne/reliance-g6101d/reliance-g6101d_installation-and-operation-manual_3948334010.webp)
6
920943 Rev E July 2014
United States Environmental Protection
Agency
Office of Underground Storage Tanks
401 M St., SW (05-400WF)
Washington, DC 20640
(703) 308-8850 (Underground Storage Tanks)
U. S. Department of Labor,
Occupational Safety and Health Administration
(OSHA) Washington, DC 20402
• Call OSHA at (202) 523-8148 to determine
specific needs; OSHA rules are covered by Title
29 of the Code of Federal Regulations (29 CFR.)
• Order OSHA publications from:
Government Printing Office (GPO)
Washington, DC 22304
(202) 783-3238
Western Fire Chiefs Association
5360 South Workman Mill Road
Whittier, CA 90601
(213) 699-0541
NOTE: Other regulatory codes may apply. Consult your local and regional code requirements to
determine which codes are applicable for your location.
2.2 Safety
Precautions
NFPA 30A states that:
“When maintenance to Class I dispensing devices becomes necessary and such maintenance is
capable of causing the accidental release or ignition of liquid, the following precautions shall be
taken before such maintenance is begun:
Only persons knowledgeable in performing the required maintenance shall perform the
work.
All electrical power to the dispensing devices, to the pump serving the dispensing devices,
and to all of associated control circuits shall be shut off at the main electrical disconnect
panel.
The emergency shutoff valve at the dispenser, if installed, shall be closed.
All vehicular traffic and unauthorized persons shall be prevented from coming within 20 ft. (6
m) of the dispensing device
1
.”
Electric shock hazard! More than one disconnect switch may be required to de-energize the
pump for maintenance and servicing. Use a voltmeter to make sure ALL circuits in the
dispenser are de-energized. Failure to do so may result in serious injury.
Lockout/Tagout requirements of the U. S. Dept. of Labor, Occupational Safety and Health
Administration (OSHA) may also apply. Refer to Title 29, Part 1910 of the Code of Federal
Regulations (29CFR1910),
Control of Hazardous Energy Source (Lockout/Tagout)
.
1. Reprinted with permission from NFPA 30A,
Code for Motor Fuel Dispensing Facilities and Repair
Garages 2000 Edition
, Copyright ©2000, National Fire Protection Association, Quincy MA 02269. This
reprinted material is not the complete and official position of the National Fire Protection Association
on the referenced subject, which is represented only by the standard in its entirety.
WARNING
Содержание Reliance G6101D
Страница 8: ...4 920943 Rev E July 2014...
Страница 20: ...16 920943 Rev E July 2014...
Страница 24: ...20 920943 Rev E July 2014...
Страница 32: ...28 920943 Rev E July 2014...
Страница 33: ...920749 Rev G 7 2014 29 APPENDIX A DIMENSIONS BASE LAYOUTS...
Страница 36: ...32 920749 Rev G 7 2014 Rotate Upwards 26 301 4 Hose Mast Dimensions...
Страница 40: ...36 920749 Rev G 7 2014...