Wayne FloodAlert 370700-001 Скачать руководство пользователя страница 3

3

WSA120

www.waynepumps.com

During a flood emergency the  warning 
beeper volume can be reduced or 
turned off completely. The mute button 
(Fig. 10) can be used to temporarily 
silence the alarm. Remember to turn 
the beeper back on after the issue in 
the sump pit has been resolved.

OPtIONAl: ADDING ADDItIONAl 
tRANSMIttERS

The receiver is capable of monitoring up 
to four different sump pits.  Transmitters 
for homes with multiple sump pits may 
be purchased separately.  additional 
programming steps are required for 
multiple monitoring stations.

For additional transmitters call 

WAYNE pumps at 1-800-237-0987 

to order part number: 66902-001

CODE CONNECtORS

The code connectors consist of 
6 movable circuits on both the 
transmitter and receiver. The code 
connectors are required for the sensor 
to communicate with the receiver.

Open the top cover of the sensor 

(Fig. 9) and the back cover of the 
receiver (Fig. 10) for access to the 

code connectors. Both sets of code 

connectors must match for the Wireless 
alarm to work properly. 
These code connectors can be set at 

any random pattern. Be sure to use the 

same pattern on the receiver that is 
used on the transmitter. 

Operation 

(continued)

each circuit can be positioned 3 ways.

1. Positive (+): circuit 

connects the "0" 
prong and the "+" 
prong.

2. negative (-): circuit 

connects the "0" 
prong and the "-" 
prong.

3. Zero (0): circuit is 

removed

Use the clip provided (Fig. 11) to set the 
code connectors properly. 

NOTE:

 if You experience interfer-

ence from a nearbY sYstem, which 
could accidentallY triGGer Your 
sYstem, please chanGe the code 
settinGs on the sensor and receiv-
er. the code settinG on the sensor 
and receiver must match after 
chanGinG the code settinG. 

zONE CONNECtORS

The receiver can work with up to 4 dif-
ferent sensors. There are 4 different 
lights on the receiver that correspond 
to each zone. 

On the transmitter, there are 2 connec

-

tors that determine zone numbers 1, 
2, 3 and 4. These 2 connectors can be 
found by opening the top plastic cover, 
near the code connectors with marking 

“A” & “B” (Fig. 12). 

Please follow table a to set the zone. 

• A positive sign (+) means the 

connector is placed on the posts.

• Negative sign (–) means the 

connector is removed from the posts.

after setting up all the connectors, both 
units are ready to be powered up.
Plug in the adapter to the receiver, the 
green LeD will start flashing, indicating 
the receiver unit is powered up but no 
sensor is detected.
Remove the top cover of the sensor 

and insert the 3V lithium battery to the 

transmitter (Fig. 5).
after inserting the battery to the water 
sensor, the receiver will beep and the 
green LeD on the receiver will stop flash-
ing and stay on. 

NOTE: 

if the liGht continuees to 

flash, lift up the float to reset 
the sYstem

NOTE:

 onlY the sensor portion of 

the water sensor is waterproof, 
the transmitter portion should 
never be submerGed in water.
Put the top cover back on and you are 
now ready to mount the water sensor.

1 2 3 4 5 6

figure 12: zone connectors (transmitter)

ZONE 

CONNECTORS

1 2 3 4 5 6

figure 9: Code Connectors (transmitter)

CODE 
CONNECTORS

figure 11: Connection Removal

1

2 3

4 5

6

figure 10: Code Connectors (Receiver)

CODE 
CONNECTORS

tAblE A

zONE

A

b

example

zone 1

+ +

zone 2

+ –

zone 3

– +

zone 4

– –

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

1 2 3 4 5 6

0

a

a

a

a

B

B

B

B

Содержание FloodAlert 370700-001

Страница 1: ...harge piping when pump is connected to electrical power Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water Fatal electrical shock could occur 1 Unplug...

Страница 2: ...a smooth flat surface Fig 6 NOTE It is beneficial to mount the transmitter as high as possible to improve range Attach the transmitter with the suction cup provided on the back of the transmitter If...

Страница 3: ...e setting zone Connectors The receiver can work with up to 4 dif ferent sensors There are 4 different lights on the receiver that correspond to each zone On the transmitter there are 2 connec tors tha...

Страница 4: ...including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to associated equip ment cost of capital cost of substitute products facilities s...

Страница 5: ...au courant Ne jamais manipuler de pompe ou de moteur de pompe avec les mains humides ou debout dans l eau ou sur une surface humide On pourrait avoir un choc lectrique mortel 1 D brancher la pompe de...

Страница 6: ...une surface plat et lisse Fig 6 REMARQUE IL EST PREFERABLE DE MONTER LE TRANSMETTEUR AUSSI HAUT QUE POSSIBLE POUR AMELIORER LA PLAGE FIXER LE TRANSMETTEUR AVEC LA VENTOUSE FOURNIE A L ARRIERE DU TRAN...

Страница 7: ...ZONE Le r cepteur peut fonctionner en utilisant jusqu 4 diff rents capteurs Il y a 4 diff rents voyants sur le r cepteur correspon dant chaque zone Sur le transmetteur il y a 2 connecteurs qui d term...

Страница 8: ...s la perte d usage des produits ou de tout quipement associ dommage l quipement associ co t de capital co t de produits de remplacement am nagements services ou capacit de remplacement co t de temps q...

Страница 9: ...la bomba est conectada a la corriente el ctrica Nunca manipule la bomba ni el motor de la bomba con las manos h medas o cuando se encuentre sobre una superficie h meda o mojada ni dentro del agua Corr...

Страница 10: ...cie lisa y plana Fig 6 NOTA CONVIENE INSTALAR EL TRANSMISOR LO M S ALTO POSIBLE PARA MEJORAR EL ALCANCE PEGUE EL TRANSMISOR CON LA VENTOSA QUE SE PROPORCIONA EN LA PARTE TRASERA DEL TRANSMISOR SI FUER...

Страница 11: ...SOR Y EL RECEPTOR DEBE COINCIDIR DESPU S DE CAMBIAR LA CONFIGURACI N DE C DIGO CONECTORES DE ZONA El receptor puede funcionar con hasta 4 sensores diferentes Hay 4 luces diferentes en el receptor que...

Страница 12: ...o del producto o cualquier equipo asociado da os al equipo asociado costo de capital costo de productos sustitutos instalaciones poderes de servicio o reemplazo costos de inutilidad o reclamos de clie...

Отзывы: