background image

11 

 

 

10 

Transmitter Security Code Change and Programming - Continued 

(see Diagram 10 on page 9 of Drawings of Installation, Use and Maintenance manual) 

 

Tools Needed: 

 

None 

 

 

NOTE

: The opener can be activated by up to six remote control devices (including Wall Station and keyless entry controls). If a 

seventh control is programmed, one of programmed controls will be over ridden and will no longer activate the opener. 

 

To clear programming of all remote control devices, press and hold opener program button (1w) for approximately ten seconds. 

When the opener beeps three times, all remote controls are erased. 

 

NOTE

: Manually disconnect the opener using the emergency disconnect handle prior to erasing remote controls.

 

 

11 

Performing Install Routine 

(see Diagram 11 on page 9 of Drawings of Installation, Use and Maintenance manual) 

 

Tools Needed: 

 

None 

 

 

 

WARNING

 DURING INSTALL ROUTINE, DOOR WILL MOVE UP AND DOWN TWICE. WATCH THE MOVING 

                                     DOOR AND KEEP PEOPLE, AND OBJECTS AWAY FROM THE DOOR UNTIL IT IS COMPLETELY 
                                     CLOSED. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR! 

 

If no obstructions interfere with the door opening completely, proceed with INSTALL ROUTINE WITH STANDARD UPPER 

LIMIT. However, if an object such as a ceiling beam obstructs the door from opening completely, set a custom upper limit 
setting during the install routine, INSTALL ROUTINE WITH CUSTOM UPPER LIMIT. 

 

IMPORTANT

: Door must be in its fully closed position to initiate install routine. 

 

INSTALL ROUTINE WITH STANDARD UPPER LIMIT USING WALL STATION WHEN SUPPLIED: 

Press and hold the profile button (2c) for five (5) seconds. The opener will beep twice, indicating the activation of the install 

routine, release the profile button (2c). The door will now move to the fully open position and stop. Then, the door will close 

completely. Next, the door will go through one more up/down cycle. Once this is complete, the door limits are set and the install 
routine is complete. 

 

INSTALL ROUTINE WITH STANDARD UPPER LIMIT USING TRANSMITTER WHEN WALL STATION IS NOT SUPPLIED: 

Press and hold the two small buttons of the transmitter (2n and 2m) 

simultaneously

 for five (5) seconds. The opener will beep 

twice, indicating the activation of the install routine, release the transmitter’s buttons (2n and 2m). The door will now move to 

the fully open position and stop. Then, the door will close completely. Next, the door will go through one more up/down cycle. 

Once this is complete, the door limits are set and the install routine is complete. 

 

INSTALL ROUTINE WITH CUSTOM UPPER LIMIT: 

Press and hold the profile button (2c) of the wall station (or the two small buttons of the transmitter (2n and 2m) 

simultaneously

) for five (5) seconds. The opener will beep twice, indicating the activation of the install routine. When the door 

moves to the desired height, at least 1,2 m off the ground, press the up/down button (2d) on the wall station (or the 

programmed button on the transmitter). The door will stop and then close completely. Next, the door will go through one more 
up/down cycle. Once this is complete, the door limits are set and the install routine is complete. Alternate: after an install routine 

has been completed, the door can be disconnected and manually moved to the desired upper limit. Reconnect door and initiate 

a new install routine from the new upper position.

  

 

 

12 

Detent Pin adjustment 

(see Diagram 12 on page 9 of Drawings of Installation, Use and Maintenance manual) 

 

Tools Needed: 

 

Screw Driver (Flat 

Head) 

  

 

IMPORTANT

: FOR SYSTEM SECURITY: The motor is designed to pivot down after the door closes completely. If the motor 

does not pivot or pivots too soon, the detent may need to be adjusted in order for the door lock feature to work properly. 

 

The amount of pressure the opener uses to pivot motor and lock arm downward is preset at factory via detent pin adjusting 

screw (2g). Since all door counterbalances are different, detent position is preset for an optimal balanced door. If door is out of 
balance slightly, a detent pin adjustment will need to be made with a screwdriver in order for proper pivoting of the motor. 

 

Содержание Optimal

Страница 1: ...ual of Installation Use and Maintenance In Between Jambs With Integrated Operator I Drive Models Wayne Dalton Optimal Wayne Dalton Confort Wayne Dalton Diffusion Wayne Dalton Prestige 40mm Pinnacle Wa...

Страница 2: ...0 11 Performing Install routine 11 Detent Pin adjustment 11 12 Custom Settings 12 Tests 12 CE Serial number label 12 USE Important Safety instructions For Use 13 Wall Station Operation 14 Transmitter...

Страница 3: ...ompletely closed NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR 14 KEEP THE GARAGE DOOR PROPERLY BALANCED an improperly balanced door could cause severe or fatal injury Have an authorized qualified doo...

Страница 4: ...SAFETY Personal Automatic obstruction sensing Push button for automatic stop in up or down direction Electronic Automatic up down force adjustment Electrical Low voltage wireless push button Limit adj...

Страница 5: ...6 Track Bolt 10 A7 6 mm 1 4 20 Flange Hex Nut 10 A8 8 x 40 mm 5 16 x 1 5 8 Lag Screw 13 A9 Molded Transition Track 1 Pair A10 Anchors 13 not supplied A11 Disconnect label 1 A12 Wall Station assembly 1...

Страница 6: ...1 4 20 x 9 16 track bolt A6 and 6mm 1 4 20 flange hex nut A7 as shown in FIG 1 2 and 1 3 Repeat for right hand side NOTE ensure the 6 x 15mm 1 4 20 x 9 16 track bolt is going through the molded trans...

Страница 7: ...track bolt A6 and 6mm 1 4 20 flange hex nut A7 for attaching to perforated angle not provided Repeat for the left hand side Verify that the tracks A2 are level and perpendicular to the inside face of...

Страница 8: ...base A12 1 two Philips head screws A12 4 Use holes needed to ensure the base is securely mounted with both screws If fastening into drywall or concrete proper anchors will need to be used IMPORTANT Ov...

Страница 9: ...WAY IF IN DOUBT CONTACT A QUALIFIED ELECTRICIAN NOTE Make sure there are no obstructions that may interfere with the garage door during operation prior to electrically connecting the opener Locate po...

Страница 10: ...pidly Once the LED 2f starts blinking release the large transmitter button 2e the LED 2f will turn off Immediately press and hold the large transmitter button 2e again LED 2f will light for approximat...

Страница 11: ...OUTINE WITH STANDARD UPPER LIMIT USING TRANSMITTER WHEN WALL STATION IS NOT SUPPLIED Press and hold the two small buttons of the transmitter 2n and 2m simultaneously for five 5 seconds The opener will...

Страница 12: ...e opener will beep once The pet button is now programmed to automatically open door to this custom height NOTE activation of normal install routine always sets pet position opening to default 200 mm h...

Страница 13: ...perly balanced door could cause a severe or fatal injury Have a qualified service person make repairs to the cables spring assemblies and other hardware 8 SAVE THESE INSTRUCTIONS DOOR ACTIVATION Upon...

Страница 14: ...n button stopping or reversing door immediately The pet feature allows for custom setting of pet position door height See Custom Settings Step 13 NOTE A door in the pet position open 200 mm 750 mm is...

Страница 15: ...nance manual Inability to activate door using transmitter A13 or wall station A12 may be caused by a weak or dead battery Press and hold door activation button on either transmitter or wall station If...

Страница 16: ...or bolts Track rollers and door track The door should open and close smoothly Ensure the door rollers are rotating freely when opening and closing the door Should the rollers not turn easily or not t...

Страница 17: ...finger ensuring it seats properly in between the teeth of the gear 1t as shown in FIG 18 2 and then gently release the wrench B4 and B5 clockwise for the right side counter clockwise for the left sid...

Страница 18: ...inted must not be too smooth or the paint will not adhere to it see NOTE no 2 It is advisable to test in an inconspicuous area to evaluate adhesion If poor adhesion is observed surface preparation for...

Страница 19: ...Light Fixture Screw In Model no 3940 CESS Part no 295522 Keyless Entry RF Transmitter Model no KEP2 B433 Part no 298393 5 Button Wall Station RF Transmitter Model no 5BWS 433 Part no 294394 3 Button...

Страница 20: ...nce condition Contact authorized qualified door system service representative Door does not close properly Cables are not on drum properly Apply constant pressure to Wall Station up down button to clo...

Страница 21: ...sconnect Cable C9 296976 3 048 m Power Cord C10 296412 Roller Assembly C11 294369 PCB Motor Control Complete C12 294389 3 Button Transmitter C13 320211 Snubber Left Hand C14 320212 Snubber Right Hand...

Страница 22: ...turer shall upon notification correct product nonconformities by repairing replacing or refunding the original purchase price of any defective part s The charges that will be covered include those as...

Страница 23: ...nstallation Use and Maintenance conform to the above listed Directives and Standards Signature of manufacturer Fran ois M dart President Wayne Dalton Europe November 10 2005 Place Wayne Dalton Europe...