30
•
SmartSensor V User Guide
2
Use the included screws to mount the Standard Preassembled
Backplate in the traffic cabinet.
Lightning
Surge
Protection
Wavetronix
Pr
ot
ec
ted
Pr
ot
ec
ted
Click!
200
RS
-485
RS
-232 DCE
110 V
AC
Smar
tS
ensor
GND
GND
RD
TD
CTS
RTS
GND
485+
485-
GND
-DC
+DC
L
N GG
L
GND
GND
RD
TD
CTS
RTS
GND
485+
485-
GND
-DC
+DC
Figure 27.
Connecting power cable to terminal blocks
3
Start by connecting the power cable. This backplate is shipped
from Wavetronix with the conductors in the cable already ter-
minated in a terminal block plug. Insert this plug into the power
terminal blocks.
4
If for some reason the conductors aren’t terminated into the
terminal block plug, terminate them by inserting each conduc-
tor into the corresponding round hole on the plug (match each
conductor to the label of the same color on the plug). Insert
a small screwdriver into the square hole above it, and rock
upwards to secure the conductor in place. Repeat with each
conductor.