CHAPTER 7
• CLICK 512
73
Note
If you do not save your settings to your Click 512, they will be lost the next time you
power the device down.
˽
The
Tools
menu contains five options for working with your device.
Reset > System
power cycles your device, while
Reset > Factory Default
restores your device to the
settings with which it was shipped.
Restore
will restore the driver to the settings cur-
rently saved on the Click 512, erasing any unsaved changes.
Upgrade
can be used to
manually upgrade to the most current firmware for your device.
Hex View
changes the
view of certain settings in the driver to hexadecimal.
˽
Clicking the
Quit
menu exits the driver and returns you to the Click Supervisor main
page.
Connecting to a Contact Closure Device
Once you have finished the computer configuration, connect the Click 512 to a contact clo-
sure device, specifically the Click 104, Click 112 or 114. Enter Device Setup mode through
the menu selection process (green solid), attach the device via the RS-485 top port, then
put the contact closure device in AC (Actuation) mode (see the appropriate chapters of the
Click 100–400 Series User Guide for information on how to enter actuation mode for the
Click 104/112/114).