The following settings are common to all four application drivers:

Setting

Description

Description

Shows a description of the device being configured. This is only for your information and does not 

affect the operation of the device.

Location

Displays the location of the device being configured. This is only for your information and does not 

affect the operation of the device.

Device ID

Gives the ID number of the device being configured, which is used to identify the device when you 

are connecting to it. By default, this number is the last five digits of the serial number, which can be 

found under the About tab or on the barcode sticker on the bottom of the device. It is recommended 

that you do not change this number unless another device on your network has the same ID number.

RF Channel

Specifies the frequency channel of the device (the channels range from 0 to 47). Each client 

and server must be on the same channel. It is recommended that each system be on a different 

channel, since the ranges on these devices extend for miles and sharing the same channel with 

another location could result in interference.

Tx Power (1W Max)

Allows you to modify the power level in increments of 10%. The Click 400 transmit power can be 

reduced to decrease interference caused by multiple radios.

Baud Rate

Allows you to change the baud rate at which the device connects to the sensor.

Under the 

About

 tab, you can view information about your Click 400 (see the figure and table below).

The following settings are common to all four application drivers:

Содержание Click 400

Страница 1: ...nicate perfectly Physical Features The Click 400 has several communication ports as well as features for configuration T Bus Connector RS 485 Connector RS 232 Connector Antenna Connector LED Indicator...

Страница 2: ...ion section of this document The front also has a push button labeled Mode Switch which is used to cycle the Click 400 through operation modes This will be discussed in the On device Configuration sec...

Страница 3: ...LED will be solid If the blue LED does not turn on then the client cannot find a server 4 Once you re sure the client has found a server watch the LEDs on the client to see the results of the link tes...

Страница 4: ...the SmartSensor Server driver To see advanced settings use the Expert driver This driver which exposes every available field for the Click 400 should only be used under the direction of Wavetronix Sup...

Страница 5: ...f the device It is recommended that you do not change this number unless another device on your network has the same ID number RF Channel Specifies the frequency channel of the device the channels ran...

Страница 6: ...the top of the screen to save your settings return to the Select Driver screen and more The Save menu allows you to save your settings Select Save to File to save your settings to a file Selecting th...

Страница 7: ...Shows the version of firmware your device currently has installed If Click Supervisor detects a discrepancy between this version and the most current version it currently has access to you will be pro...

Страница 8: ...see the figure and table below Setting Description Command Allows you to set the command sent from the device during the autobaud process Don t change these values unless instructed to by Wavetronix...

Страница 9: ...t Address RF Delivery Allows you to send to a specific address or broadcast to all radios If the device is set up as a client select Address if the device is set up as a server select Broadcast Auto D...

Страница 10: ...ntil your buffer is full before sending Transmit Retries Allows you to set the number of times the radio will transmit after not getting a response Address mode Broadcast Attempts Allows you to set a...

Страница 11: ...electing this will open a directory box allowing you to name your settings file This file will always be saved in the Wavetronix folder created when you installed Click Supervisor under Wavetronix Cli...

Отзывы: