background image

Wiring AC power in

Follow the steps below to properly wire an AC to DC power conversion module:

Mount the Click 201/202/204 onto the DIN rail.

Connect the line (hot) wire from the Click 230 into the L screw terminal on the top of the 

Click 201/202/204. The line wire is usually black.

Connect the neutral wire from the Click 230 to the N screw terminal to the top of the Click 

201/202/204. The neutral wire is usually white.

Wiring DC power out

To power the sensor, 10–30 VDC needs to be connected to the Click 200 in the pole-mount 

cabinet. Additionally, if there is a main traffic cabinet connected by a homerun cable, you will 

need to connect DC power to the Click 200 in that cabinet.

Connect a +DC conductor (usually a red wire) to the + screw terminal on the bottom of the 

Click 201/202/204.

Connect a -DC conductor (usually a black wire) to either of the - screw terminals on the 

bottom of the Click 201/202/204.

Note. 

Do NOT connect to the DC OK screw terminal.

Some installations use a Click 203 instead of a Click 201/202/204. The Click 203 is covered in 

Part 7 of this document.

5

  Wire the Click 201/202/204 AC to DC converter

4

  Wire the Click 230 AC surge

Follow the steps below to install the AC surge protection:

Mount the Click 230 onto the DIN rail.

Connect the line (hot) wire from the Click 210 terminal to terminal 5 on the IN side of 

the Click 230.

Connect the neutral wire from the AC terminal block or cord to the terminal marked 1 

on the Click 230.

Connect the ground wire from the AC terminal block or cord to the terminal marked 3 

on the Click 230.

Connect the outgoing and protected neutral wire to the terminal marked 2 on the 

Click 230.

Connect the outgoing and protected line wire to the terminal marked 6 on the Click 230.

Ground the system to the terminal marked 4 on the Click 230. 

DC power (+)

 

Ground (-)

 

Отзывы: