Once the power plant is attached
to the DIN rail and wired correctly,
follow the steps below to verify your
connections:
1
Push the blue switch down on
the front of the Click 210 circuit
breaker.
2
Make sure that the Click
201/202/204 DC OK light is on.
7
(Optional) Wire the Click 203
6
Verify power is connected
If you are using the Click 203 UPS and battery module, follow
the steps below to correctly wire it:
1
Wire AC power into the UPS module by connecting the AC
line (black wire) to the L (+) terminal.
2
Connect the AC neutral (white wire) to the N (-) terminal.
3
Wire the supplied red wire from the + Battery terminal on
the UPS to the + OUT terminal on the battery.
4
Wire the supplied black wire from the - Battery terminal to
the -DC terminal on the battery.
5
DC power can be wired out of the UPS module by connect-
ing to the + and - OUT DC 24V 2A terminals.
6
Short R1 and R2. If you don’t, the UPS will not switch over to
the battery when the power goes out.
WX-500-0174
© 2021 Wavetronix LLC. All rights reserved. Protected in the US by patents viewable at www.wavetronix.com/en/legal. Protected by Canadian Patent Nos. 2461411; 2434756; 2512689; and European Patent Nos. 1435036;
1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Command and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are
trademarks or registered trademarks of their respective holders. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability
related to its use.
Black (live)
Green (ground)
White (neutral)
Black (ground)
Red (+24 VDC)
AC
power
source