Appendix A - NCL INTERFACE _______________________________ Boomer-III User Manual & Integrator’s Guide
Copyright Wavenet Technology © October 2003
90
BM310012WT04
FORMAT:
WN_SET_PARAM Command Syntax (NCL string “ZF^…”):
WN_SET_PARAM Response Syntax:
OPERAND DESCRIPTIONS AND RESPONSES:
The various Vendor Parameter settings that can be made are described
as follows. Please note that all multiple byte fields are stored MSB
first. Numbers prefixed with “0x” are expressed as hexadecimal.
“Byte” (optionally followed by a sequence number) is used to indicate
a single byte.
Parameter Number
A 16-bit field, which is unique to each
parameter, used to differentiate them.
Parameter Length
A 16 bit field, which indicates the length
of the following parameter, in bytes.
Parameter Contents
The actual bytes set for the parameter.
The format is parameter specific.
The
Parameter Name
is a label used to refer to particular parameters,
and is used as a definition for the parameter number.
WN_SET_PARAM
:
Set Modem Configuration (NCL string
“ZF^[2 byte parameter number][2 Byte
parameter length][parameter block..]”).
Parameter name :
WN_PWR_SAVE_MODE
Parameter number :
0x7000 (“Byte1Byte2”) (ASCII 0x70 = ‘p’)
RESP
Length
SDU Tag
VENDOR
SUCCESS
VEND_WAVENET
CMND
Length
SDU Tag
VENDOR
‘Z’
‘F’
‘^’
WN_SET_PARAM
VEND_WAVENET
Parameter number Parameter length
Parameter
contents …